16. TECH. REP. MODE
Field Service Ver. 2.0 Mar. 2006
196
bizhub C250P
Adjustment / Setting
5
Setting the date and time for CS Remote Care
1.
Select the Detail Set: ***
→
Date/Time. (***: modem or e-mail)
2.
Press the Menu/Select key.
3.
Input the Date, Time, Time zone, and press Menu/Select key.
See P.204
6
Setting the Center ID
1.
Select the Detail Set: ***
→
Center/Device ID. (***: modem or e-mail)
2.
Input the Center ID (5 digits)
See P.204
7
Setting the Device ID
1.
Select the Detail Set: ***
→
Center/Device ID. (***: modem or e-mail)
2.
Input the Center ID (9 digits)
See P.204
8
Setting the telephone number of the Center
1.
Select the CS Remote Care
→
Detail Set:
Modem
→
Center Tel No.
2.
Input the telephone number of the Center
See P.204
Setting the E-mail address
1.
Select the Detail Set: E-mail
→
Address.
2.
Input the e-mail address of the remote desti-
nation.
See P.204
9
Inputting the Device telephone number
1.
Select the CS Remote Care
→
Detail Set:
Modem
→
Device Tel No.
2.
Input the Device telephone number
See P.204
Setting the Response Timeout
1.
Select the Detail Set: E-mail
→
Response
Timeout.
2.
Input the response timeout period.
NOTE
• Normally, leave it as the default setting.
See P.205
10
Inputting the AT command for initializing the
modem
1.
Select the CS Remote Care
→
Detail Set:
Modem
→
Initial Trans.
2.
Input AT Command.
NOTE
• Change this Command only when it is
necessary. (They do not need to be
changed in normal condition.)
• For details on AT Command, see the
manual for the modem.
See P.205
Setting the E-mail address
1.
Select the Server Setting.
See P.206
2.
Select the Server for RX, and set POP3
server address, POP3 Login name, POP3
password and POP3 port number.
3.
Select the Receive Setting, and set the E-
Mail address, Mail Check, Connection Time
Out and APOP Authentication.
4.
Select the Send Setting, and set the SMTP
server address, SMTP port number, Con-
nection Time Out, and APOP Authentica-
tion.
5.
Select the TX/RX Test, and press Start key
to carry out a transmission/reception test. If
it fails to exchange messages, see the error
message to take necessary measure, and
try again.
11
Setting the DIPSW for CS Remote Care
NOTE
• This setting is not normally necessary. Take this step only when necessary in a spe-
cific connecting condition.
Step
Procedure
Using the telephone line modem
Using E-mail
1
bizhub_C250P_Total.book 196 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......