17. Jig Soft
Field Service Ver. 2.0 Mar. 2006
218
bizhub C250P
Adjustment / Setting
17.5 Machine
17.5.1
Fusing Temperature
Functions
• To adjust individually the temperature of the Heating Roller and the Fusing Pressure
Roller for each type of paper, thereby coping with varying fusing performance under
changing environmental conditions.
Use
• When fusing performance is poor, or wax streak or offset occurs when the type of
paper is changed or environmental conditions change.
• By setting the temperature higher (+), gloss of print or OHP transparencies can be
improved.
• By setting the temperature lower (-), Exit Roller mark or uneven transparencies of
OHP can be reduced.
Adjustment
Range
Heating Roller
: 0 °C to +10 °C (step: 5 °C) ............ Thick 3
:-10 °C to +10 °C (step: 5 °C)............ others
Pressure Roller : 0 °C to +10 °C (step: 5 °C) ............ Thick 3
:-10 °C to +10 °C (step: 5 °C)............ others
Adjustment
Instructions
If fusing performance is poor, increase the setting.
If wax streaks occur, decrease the setting.
If offset is poor, decrease the setting.
Setting/
Procedure
1.
Call the Service Mode to the screen.
2.
Click these keys in this order: [Machine]
→
[Fusing Temperature].
3.
Select the paper type and Fusing Roller type.
4.
Enter the new setting from the [+] / [-] key.
5.
The temperature does not change immediately when the setting is change.
Wait a while before performing the subsequent steps.
NOTE
• As a general rule, do not adjust the fusing temperature on the pressure appli-
cation side.
6.
Click [END] to validate the adjustment value.
7.
Check the print image for any image problem.
8.
Make the adjustment for each type of paper.
bizhub_C250P_Total.book 218 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......