25. Image quality problem
Field Service Ver. 2.0 Mar. 2006
354
bizhub C250P
T
roubleshooting
14
Image Process
Adjustment
→
Stabilizer
→
Reset +
Stabilizer (Service
Mode)
After the Reset + Stabilizer
sequence has been completed, run
Gradation Adjust.
NO
Go to next step.
15
The problem has been eliminated
through the checks of steps up to
14.
NO
Change Imaging Unit.
→
Change MFP Control
Board
→
Change PH Unit.
→
Change High Voltage
Unit (Image Transfer,
Neutralizing).
Step
Section
Check Item
Result
Action
bizhub_C250P_Total.book 354 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......