![Konica Minolta BIZHUB C250P Скачать руководство пользователя страница 251](http://html1.mh-extra.com/html/konica-minolta/bizhub-c250p/bizhub-c250p_service-manual_1993378251.webp)
16. TECH. REP. MODE
Field Service Ver. 2.0 Mar. 2006
210
bizhub C250P
Adjustment / Setting
000F
Transmitting RING Buffer Full
(When the Transmitting RING Buffer is full.)
• Contact responsible person of
KONICA MINOLTA.
0010
RX FIF0 ERROR
(when Read / Write error occurs at RX FIF0)
• Contact responsible person of
KONICA MINOLTA.
0011
Baud Rate ERROR
(When selected Baud Rate is out of the specifica-
tion (9600 bps to 38400 bps).)
• Check the Baud rate of the
software DipSW.
0012
TX FIF0 Level Error
(When the threshold of the selected TX FIF0 is
not error value (1, 3, 9, 13).)
• Contact responsible person of
KONICA MINOLTA.
0013
RX FIF0 Level Error
(When the threshold of the selected RX FIF0 is
not error value (0, 4, 8, 14).)
• Contact responsible person of
KONICA MINOLTA.
0014
Receiving Data Over Error
(When the data whose size exceeds the transmit-
ting RING buffer is requested.)
• Contact responsible person of
KONICA MINOLTA.
0015
Status Error
(During modem operation is being confirmed)
• Contact responsible person of
KONICA MINOLTA.
0016
Status Error (During receiving)
• Contact responsible person of
KONICA MINOLTA.
0017
Status Error
(During line is being shut down)
• Contact responsible person of
KONICA MINOLTA.
0018
Machine ID has already been registered
(Request telegram 2 (SET-UP) comes from the
main unit that has already registered Machine
ID.)
• Set the initial registrations
again for all including the host
side.
0019
Center ID Error
(Center ID of the host is not identical with the one
of start request telegram.)
• Check Center ID setting of the
main unit side.
• Check Center ID setting of the
main unit side.
001A
Device ID inconsistency
(Device ID of the host is not identical with the one
of start request telegram.)
• Check Device ID setting of the
main unit side.
• Check the setting of the host
side.
001B
Device ID Unregistered
(Request telegram 2 (Constant data transmitting,
Emergency call) comes from the main unit that
has not registered Machine ID yet.)
• Check Device ID setting of the
main unit side.
• Check the setting of the host
side.
001C
Grammar Error
(Received response telegram is unregulated for-
mat.)
• Contact responsible person of
KONICA MINOLTA.
001D
Impossible to change (Unchangeable items)
(Host requests to change the setting of items
which are not allowed to change.)
• Contact responsible person of
KONICA MINOLTA.
001E
Impossible to change (During printing)
(Setting cannot be changed because the setting
change is made during the machine is printing or
starts printing.)
• Try again when the machine is
not printing.
001F
Impossible to change (Unread items)
(The host tries to make writing on the items the
current value has not been read.)
• Contact responsible person of
KONICA MINOLTA.
Error code
Error
Solution
1
bizhub_C250P_Total.book 210 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......