23. Malfunction code
Field Service Ver. 2.0 Mar. 2006
334
bizhub C250P
T
roubleshooting
23.5.51
C4761: Compression hardware timeout
23.5.52
C4765: Extraction hardware timeout
23.5.53
C4770: JBIG0 Error
23.5.54
C4771: JBIG1 Error
23.5.55
C4772: JBIG2 Error
23.5.56
C4773: JBIG3 Error
23.5.57
C4780: Compressor 0 command buffer stop failure
23.5.58
C4781: Compressor 1 command buffer stop failure
23.5.59
C4782: Compressor 2 command buffer stop failure
23.5.60
C4783: Compressor 3 command buffer stop failure
23.5.61
C5102: Main Motor’s failure to turn
23.5.62
C5103: Main Motor Turning at abnormal timing
Relevant Electrical Parts
MFP Control Board (PWB-MFP)
DIMM0 (Work0)
DIMM1 (Work1)
Step
Action
1
When the error is displayed after the memory check, remove and insert the DIMM0 and DIMM1
again to recheck (C4765).
2
Change PWB-MFP
Relevant Electrical Parts
Main Motor (M1)
Mechanical Control Board (PWB-M)
DC Power Supply (PU1)
Step
Action
1
Check the M1 connector for proper connection and correct as necessary.
2
Check M1 for proper drive coupling and correct as necessary.
3
Check the PWB-M connector for proper connection and correct as necessary.
4
M1 operation check
5
Change PWB-M
6
Change PU1
Relevant Electrical Parts
Main Motor (M1)
Mechanical Control Board (PWB-M)
DC Power Supply (PU1)
Step
Action
1
M1 operation check
2
Change PWB-M
3
Change PU1
bizhub_C250P_Total.book 334 ページ 2006年3月27日 月曜日 午前8時28分
Содержание BIZHUB C250P
Страница 1: ...SERVICE MANUAL FIELD SERVICE...
Страница 3: ...ii Blank Page...
Страница 26: ...SERVICE MANUAL 2006 03 Ver 2 0 FIELD SERVICE Main Unit...
Страница 49: ...4 Paper path Field Service Ver 2 0 Mar 2006 8 bizhub C250P General 4 Paper path 4038F1C404AA...
Страница 329: ...21 Mechanical adjustment Field Service Ver 2 0 Mar 2006 288 bizhub C250P Adjustment Setting Blank Page...
Страница 415: ...26 Controller trouble Field Service Ver 2 0 Mar 2006 374 bizhub C250P Troubleshooting Blank Page...
Страница 422: ......