Field Service Ver. 2.0 Mar. 2006
10. Firmware upgrade
61
bizhub C250P
Maintenance
10.2.4
Writing into the Compact flash
1.
Put the data of Firmware in the optional directory. (C:\C250P in the below figure)
NOTE
• The file name of Firmware data consists of the “Release
Date_Version_CHECKSUM-****.exe.”
2.
Double-click the Firmware data, and specify the directory to be uncompressed, and
then uncompress it.
NOTE
• When old Firmware is still left in the specified directory to be uncompressed,
delete it before uncompressing.
4038F2E600DA
C:\C250P
4038F2E601DA
C:\C250P