DIAGNOSTICS
Error Codes
10DEC05
DG4825-1
Page
81 of 180
12903 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
12904 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
12905 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
12906 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
Description: The SLOW SCAN AY did not move to the home position. The command
is executed again.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: The COARSE NUDGE UP command did not occur. The command is
executed again.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: The COARSE NUDGE DOWN command did not occur. The command is
executed again.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: The FINE NUDGE UP command did not occur. The command is
executed again.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the