DIAGNOSTICS
Error Codes
10DEC05
DG4825-1
Page
67 of 180
11009 - DUPLEX CAM: Move failed
11010 - DUPLEX CAM: Software command failed on the MSC BD
11014 - DUPLEX CAM: Timeout Error
11015 - Move command failed because SLOW SCAN not at Home Position
11016 - MSC BOARD A1: Software Error for DUPLEX CAM
Cause:
The DUPLEX CAM malfunctioned.
Action:
Do the checkout for the
Description: The DUPLEX CAM received a command to move that was not correct.
Cause 1: The DUPLEX CAM malfunctioned.
Action:
Do the checkout for the
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Do the checkout for the
MOTION SYSTEM CONTROL BOARD A1
Description: The DUPLEX CAM did not move in the time allowed.
Cause:
The DUPLEX CAM malfunctioned.
Action:
Do the checkout for the
Cause 1: The DUPLEX CAM malfunctioned.
Action:
Do the checkout for the
Cause 2: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: The MOTION SYSTEM CONTROL BOARD A1 did not provide the RTXC
TIMER. This TIMER determines the timeouts for the motion of the
DUPLEX CAM.