DIAGNOSTICS
Error Codes
10DEC05
DG4825-1
Page
84 of 180
12941 - Unexpected Retry during Communication to MOTION SYSTEM
CONTROL BD
ERASE LAMPS
13001 - 13008 ERASE LAMP PAIRS
Description: A message could not be sent to the SLOW SCAN CONTROLLER
BOARD A6. The command is executed again.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Code
Log Message
13001
ERASE LAMP PAIR No. 1 is out
13002
ERASE LAMP PAIR No. 2 is out
13003
ERASE LAMP PAIR No. 3 is out
13004
ERASE LAMP PAIR No. 4 is out
13005
ERASE LAMP PAIR No. 5 is out
13006
Two ERASE LAMP PAIRS are not functioning
13007
Three ERASE LAMP PAIRS are not functioning
13008
Four ERASE LAMP PAIRS are not functioning
Cause:
One or more ERASE LAMP PAIRS malfunctioned.
Action:
Install a new ERASE LAMP PAIR.