DIAGNOSTICS
Using the Diagnostics
10DEC05
DG4825-1
Page
44 of 180
5
Check that the SENSORS match the table during the correct action.
6
If the SENSORS do not match the table, check the error log. See
7
for the possible cause and action for the problem.
Action
S1
S2
S3
S5
S8
S9
A8 CAM
Inner
A8 CAM
Outer
Loading CASSETTE
X
X
X
X
Loading PLATE
X
X
X
X
X
Returning PLATE to CASSETTE
X
X
X
X
X
Ejecting CASSETTE
X
X
X
X
X
X