DIAGNOSTICS
Error Codes
10DEC05
DG4825-1
Page
72 of 180
12012 - SLOW SCAN AY: Timeout Error
12013 - SLOW SCAN AY: Timeout error
12014 - MSC BOARD A1: Software Error for SLOW SCAN
12100 - SLOW SCAN CONTROLLER BOARD A6: Software Error
Description: The PLATE did not move within the correct time.
Cause:
A malfunction occurred in one or more of the following components:
•
COIL BOARD
•
SLOW SCAN AY
Action:
1.
Check for an obstruction.
2.
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: A command for the PLATE that is not correct was made by the system
software.
Cause:
The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Do the checkout for the
MOTION SYSTEM CONTROL BOARD A1
Description: This error might occur during the diagnostics if the service person starts
to move the PLATE before the PLATE stops moving.
Cause:
The SLOW SCAN AY malfunctioned.
Action:
Do the checkout for the
SLOW SCAN CONTROLLER BOARD A6 and COIL
Description: The SLOW SCAN AY will not move.
Cause:
The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
1.
Energize and de-energize the CR 825/850 SYSTEM.
2.
Do the checkout for the