KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 6
PARAMETER DESCRIPTIONS
113
fSTS:4 – Float LC Raw Voltage (V)
Variable Units: Volts
Description: This parameter shows the actual unbiased voltage of the float load cell. This is the load cell that
measures the weight being suspended by the system.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Float Load Cell \ Row 1.
fSTS:5 – Part Weight (lbs)
Variable Units: Pounds
Description: This parameter shows the weight that is currently suspending from the inline handle minus the
system’s fixture weight.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Fixture Weight \ Row 1.
fSTS:6 – Active Up Stop Weight (lbs)
Variable Units: Pounds
Description: This parameter shows the active weight limit that will trigger an Up Stop fault which will inhibit
further upwards motion. This parameter changes depending on which mode has currently been selected.
KSS Workspace tree location: Knight WO# \ Troubleshooting \ Can’t Move Up \ Step 2.
fSTS:7 – Active Down Stop Weight (lbs)
Variable Units: Pounds
Description: This parameter shows the active weight limit that will trigger a Down Stop fault which will inhibit
further downwards motion. This parameter changes depending on which mode has currently been selected.
KSS Workspace tree location: Knight WO# \ Troubleshooting \ Can’t Move Down \ Step 2.
fSTS:8 – Active Reverse/Upper Limit (in)
Variable Units: Inches
Description: This parameter shows the upper travel limit that is currently in effect. This parameter changes
depending on which mode has currently been selected.
KSS Workspace tree location: Knight WO# \ Troubleshooting \ Can’t Move Up \ Step 3.
fSTS:9 – Active Forward/Lower Limit (in)
Variable Units: Inches
Description: This parameter shows the lower travel limit that is currently in effect. This parameter changes
depending on which mode has currently been selected.
KSS Workspace tree location: Knight WO# \ Troubleshooting \ Can’t Move Down \ Step 3.
fSTS:10 – Command Velocity (ips)
Variable Units: Inches per second
Description: This parameter displays the instantaneous commanded velocity of the hoist.
fSTS:11 – Current Velocity (ips)
Variable Units: Inches per second
Description: This parameter displays the current feedback velocity of the hoist.
KSS Home screen location: Quick View panel \ Row 2 (Lower right-hand portion of the screen).
fSTS:12 – Lift Load Cell Pounds (lb)
Variable Units: Pounds
Description: This parameter displays the amount of force applied to the lift load cell in pounds.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Lift Load Cell \ Row 4.
fSTS:13 – Encoder Offset Record
Variable Units: Inches
Description: This parameter displays the recorded offset of the encoder at the hoist’s home position.
KSS Workspace tree location: Knight WO# \ Setup \ Position Calibration \ Row 3.
fSTS:14 – Active Encoder Offset
Variable Units: Inches
Description: This parameter displays the active offset of the encoder at the hoist’s home position.
KSS Workspace tree location: Knight WO# \ Setup \ Position Calibration \ Row 4.