KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 6
PARAMETER DESCRIPTIONS
101
bSTS:39 – AP_Error
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if an error occurred when trying to return the actual position of the
hoist.
KSS Workspace tree location: Knight WO# \ Troubleshooting \ Fast Flashing Red Light.
KSS Workspace tree location: Knight WO# \ Status \ System Status \ Row 7.
bSTS:41 through bSTS:95 – Spare
bSTS:96 – M1-DI-0 Run Stop Ok
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #0 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:97 – M1-DI-1 Reserved
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #1 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:98 – M1-DI-2 Reserved
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #2 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:99 – M1-DI-3 Reserved
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #3 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:100 – M1-DI-4 Analog Trigger
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #4 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:101 – M1-DI-5 Green PB
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #5 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:102 – M1-DI-6 Blue PB
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #6 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:103 – M1-DI-7
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #1’s digital input #7 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:104 – M2-DI-0
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #2’s digital input #0 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.
bSTS:105 – M2-DI-1
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive’s module #2’s digital input #1 is ON.
KSS Workspace tree location: Knight WO# \ Status \ I/O Status.