KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 6
PARAMETER DESCRIPTIONS
99
bSTS:15 – Drive Alarm Active
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive is experiencing a fault. The fault code will be
listed on Row #1 of the screen.
KSS Workspace tree location: Knight WO# \ Status \ Alarms/Warnings \ Row 1.
bSTS:16 – Lift Mode Active
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive is currently in Lift mode.
KSS Workspace tree location: Knight WO# \ Status \ System Status \ Row 9.
bSTS:17 – Float Mode Active
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive is currently in Float mode.
KSS Workspace tree location: Knight WO# \ Status \ System Status \ Row 10.
bSTS:18 – Payout Mode Active
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive is currently in Payout mode.
KSS Workspace tree location: Knight WO# \ Status \ System Status \ Row 8.
bSTS:19 – Payout Allowed
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if all of the servo drive’s hardware and software are ready to
go into Payout mode.
bSTS:20 – Test Mode Active
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive is currently in Test mode.
KSS Workspace tree location: Knight WO# \ Status \ System Status \ Row 9.
bSTS:21 – Test Mode Allowed
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the servo drive may enter Test mode.
bSTS:22 – Test Counts Complete
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the Test mode has competed the number of cycles listed in
‘CYCLE COUNT TARGET’ display.
KSS Workspace tree location: Knight WO# \ Motion \ Test Mode \ Row 9.
bSTS:23 – Slow Zone Part Loaded
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the weight attached to the hoist is greater or equal to the
fPRM:55 Slow Zone Part Loaded Weight.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Slow Zone \ Row 4.
bSTS:24 – Slow Zone Enabled
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if any of the Slow Zone modes are enabled.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Slow Zone \ Row 1.
bSTS:25 – Safe Start
Variable Units: Boolean (0=Off, 1=On)
Description: This parameter displays a ‘1’ if the hoist completed a safe start.
KSS Workspace tree location: Knight WO# \ Hoist Configuration \ Lift Load Cell \ Row 5.