KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 2
INSTALLATION
11
Step 5: Control Handle Set-up
Inline Handle setup:
1) Hold the inline handle and trigger with one hand, and hold the chain away from the inline handle
with other hand. (Refer to Figure 2-19)
2) Apply upward pressure on inline handle until the green light flashes.
3) Once green light starts flashing, release the inline handle and the GREEN light will illuminate.
4) Grasp the inline handle and apply upward pressure until the chain starts feeding into the hoist.
Continue this until the inline handle is hanging vertically from the hoist at a comfortable height.
Figure 2-19
NOTE
A continuously flashing GREEN light indicates a safe start activation
fault. The system is sensing commanded motion during the Power-Up
sequence.
Remedy
Analog Handle: Release the handle and verify that the GREEN light
illuminates solid. If the GREEN light still flashes after the handle is
released, refer to section 7. “Troubleshooting”.
Step 6: Test Hoist Movement
Test the Servo Hoist movement by applying upward and downward pressure on the inline handle. The system
should move up and down freely.
Step 7: Back-Up Software
Knight Servo Hoists are pre-programmed prior to delivery. It is a good practice to back-up this software
before initial operation. Refer to the section 5. ‘Software’ portion of this manual for instructions to connect to
the Servo Hoist and to back-up the software.