Step 38.
Press the “GO TO LIFT SPEED LIMITS” button on the LIFT TRAVEL LIMITS screen.
Figure 5-62
Lift Speed Limits screen: (Refer to Figure 5-62)
Row #1) The ‘LIFT MODE SPEED LIMIT (IPS)’ display shows the highest speed allowed to be
commanded while in LIFT MODE.
The ‘ANALOG LIFT ACCEL (IPS^2)’ display shows the acceleration setpoint for analog
commanded velocity while in LIFT MODE.
The ‘ANALOG LIFT DECEL (IPS^2)’ display shows the deceleration setpoint for analog
commanded velocity while in LIFT MODE. This value should be set equal to or higher than
the acceleration setpoint for analog commanded velocity.
Row #2) The ‘DIGITAL SLOW SPEED (IPS)’ display shows the command velocity for the slow
jog function while in LIFT MODE.
The ‘DIGITAL FAST SPEED (IPS)’ display shows the command velocity for the fast jog
function while in LIFT MODE.
Row #3) The ‘DIGITAL LIFT ACCEL (IPS^2)’ display shows the acceleration setpoint for digital
commanded velocity while in LIFT MODE.
The ‘DIGITAL LIFT DECEL (IPS^2)’ display shows the deceleration setpoint for digital
commanded velocity while in LIFT MODE. This value should be set equal to or higher than
the acceleration setpoint for digital commanded velocity.
Buttons) Press the ‘GO TO LIFT TRAVEL LIMITS’ button to go to that screen.
Press the ‘BACK TO INDEX’ Button to go to the HOIST CONFIGURATION INDEX screen.
Note:
This screen will show speed limits for what is enabled on the Feature Switchboard screen
(Refer to 5.E. Step 30).