KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 5
SOFTWARE
71
(Refer to Figure 5-50)
CAUTION
Use Caution if setting the back-off distance higher than necessary as
this move will use the full peak torque settings of the drive and motor.
This is intended to release any bind created but should be used only for
that purpose.
WARNING
Torque limits set higher than 30% can cause damage or injury and
should only be used with due caution.
Row #3) The ‘PAYOUT MODE TORQUE LIMIT (%)’ display shows the amount of torque that the
motor will be limited to in Payout Mode when paying in chain, or paying out chain.
Row #4) The ‘ACTUAL TORQUE (%)’ display shows the amount of torque that the motor is running at.
Row #5) The ‘PAY IN’ button will issue a reverse/upward direction command.
There is normally a 3 second delay after issuing the command before motion starts.
Row #6) The ‘PAY OUT’ button will issue a run in forward/downward direction command.
There is normally a 3 second delay after issuing the command before motion starts.
Row #7) The ‘PAYOUT MODE INACTIVE’ indicator will change to ‘PAYOUT MODE ACTIVE’ when
the hoist is moving in Payout Mode.
Buttons) Press the ‘BACK TO INDEX’ button to return to the MOTION INDEX screen.
Press the ‘GO TO POSITION CALIBRATION’ to go to that screen.