KNIGHT D-SERIES SERVO HOIST OPERATION MANUAL
SECTION 5
SOFTWARE
89
(Refer to Figure 5-67)
Row #3) The ‘PART UNLOADED, MOVING UP BORDER POSITION (IN)’ display shows the travel
setpoint that triggers Slow Zone functions while the hoist is unloaded and moving upwards.
The ‘PART UNLOADED, MOVING DOWN BORDER POSITION (IN)’ display shows the
travel setpoint that triggers Slow Zone functions while the hoist is unloaded and moving
downwards.
The ‘SLOW ZONE PART UNLOADED SPEED (IPS)’ display shows the highest velocity that
will be commanded while the hoist is unloaded.
Row #4) The gray indicator directly below the visualization will display ‘PART LOADED’ if the weight
attached to the hoist is greater than or equal to the ‘SLOW ZONE PART LOADED WEIGHT’
or ‘PART UNLOADED’ if the weight is less than the setpoint. This also indicates which
loaded/unloaded Slow Zone border positions are active and is displayed by the
visualization.
The ‘SLOW ZONE ACTIVE’ indicator. Green = Active, Red = Inactive.
The ‘PART LOADED, MOVING UP BORDER POSITION (IN)’ display shows the travel
setpoint that triggers Slow Zone functions while the hoist is loaded and moving upwards.
The ‘PART LOADED, MOVING DOWN BORDER POSITION (IN)’ display shows the travel
setpoint that triggers Slow Zone functions while the hoist is loaded and moving downwards.
The ‘SLOW ZONE PART LOADED SPEED (IPS)’ display shows the highest velocity that will
be commanded while the hoist is loaded.
Row #5) The ‘CURRENT POSITION (IN)’ display shows the current position of the hoist in inches.
The current speed of the hoist is shown on the “CURRENT VELOCITY (IPS)’ display and the
horizontal ‘SPEEDOMETER’ bar.
Button)
Press the ‘BACK TO INDEX’ to go to the HOIST CONFIGURATION INDEX screen.
Step 44.
Press the “RESET TO DEFAULTS” button on the SETUP INDEX screen.
Figure 5-68
Reset to Default screen: (Refer to Figure 5-68)
Row #1) Ensure that the Run-Stop button is pressed before the resetting all parameters to default.
Row #2) The ‘RESET TO DEFAULT’ button will reset a large number of parameters. These settings
will return the hoist to a default set of parameters. If all the hardware is connected and in
good condition this will restore the hoist to an operable condition, with a generic set of
parameters. Use caution when operating the hoist after this change. As an example, the
default parameters will overwrite the travel limits and are set up for an eight-foot (8’) coil
cord.
If your system has a shorter cord installed you could overstretch the cable and potentially
damage it or the hoist.
After a Reset to Default occurs the Total weight reading may be off. If so, recalibrate the
Float Load Cell safely.
Button)
Press the ‘BACK TO INDEX’ button to return to the SETUP INDEX screen.