5-22 Basic Operation
PLZ-4W
5.11 Lock Function
The PLZ-4W can be locked to prevent erroneous operation such as inadvertently
changing the settings or overwriting the memory or sequence. The functions that
can be used and those that cannot be used when the lock function is enabled are
indicated below.
Table5-1
Lock function
Fig. 5-11
Keys used in the lock function
■
Setting the lock
1.
Set the lock.
Press the LOCK (SHIFT+LOCAL) key.
A key icon is indicated on the display, and the PLZ-4W is locked.
When locked, you can only carry out the following key operations: turn on or
off the load, execute sequences, recall ABC preset memories, recall setup
memories, and release the lock.
■
Releasing the lock
1.
Release the lock.
Hold down LOCK (SHIFT+LOCAL) for a few seconds until a beep is heard.
The key icon clears, and the lock is released.
■
Locking the PLZ-4W at power on
By default, the PLZ-4W is not locked at power on. You can change the setting from
the menu so that the PLZ-4W is locked at power on.
1.
Check that the load is turned off.
Check that the LOAD LED is turned off. If the LED is illuminated, press the
LOAD key to cut off the current.
Functions that can be used
Functions that cannot be used
Load on/off
Setting change
Sequence execution
Sequence construction
Lock set/clear
Memory store (save)
ABC preset memory recall
Setup memory recall
SWITCHING
ENTER
SHORT
EDIT
SLEW RATE
RUN / STOP
UVP
PAUSE
STORE
RECALL
A
B
C
LOAD
Th/TL
FREQ / DUTY
MENU
PRESET SEQ
I
LEVEL
VRANGE
RANGE
SW ON
+CV
MODE
LOAD
SET / VSET
LOCK
LOCAL
SHIFT
ABC
OPP / OCP
0.00
mA
0.000
V
0.000
W
CC
SLEWRATE
0.500
A
0.01
mA/
μ
s
SET
H 33A
150V
Key icon
Содержание PLZ-4W Series
Страница 10: ...VIII Contents PLZ 4W ...
Страница 20: ...1 10 General Information PLZ 4W ...
Страница 38: ...2 18 Installation and Preparation PLZ 4W ...
Страница 90: ...5 30 Basic Operation PLZ 4W ...
Страница 192: ...9 10 Specifications PLZ 4W ...
Страница 214: ...A 22 Appendix PLZ 4W ...