5-16 Basic Operation
PLZ-4W
5.8
CV Mode
In CV mode, you set the Voltage [V].
■
Operating procedure of CV mode
Fig. 5-7
Keys used in CV mode
1.
Check that the load is turned off.
Check that the LOAD LED is turned off. If it is on, press the LOAD key to turn
it off.
2.
Select the operation mode.
Press the MODE key.
An operation mode pop-up menu appears.
Press the MODE key repetitively until CV is highlighted on the menu.
Check that CV is indicated on the display.
3.
Select the current range.
Press the RANGE key.
A current range pop-up menu appears.
Each time you press the RANGE key while the menu is displayed, the
range switches in the order L, M, and H.
When the desired range is highlighted, stop pressing the key.
Along with L, M, or H, the full scale value of the respective range is displayed.
This value varies depending on the model.
Overview of the procedure
Select the operation mode, and set the voltage value.
Turn on the load and change the voltage value.
Finally, turn off the load to cut off the current.
Preparation
Main operation
Unit behavior
Check that the load is
turned off.
Set the operation mode.
Turn on the load.
Change the voltage
value.
Turn off the load.
The display shows the
voltage, current, and
wattage at the load input
terminal.
SWITCHING
ENTER
SHORT
EDIT
SLEW RATE
RUN / STOP
UVP
PAUSE
STORE
RECALL
A
B
C
LOAD
Th/TL
FREQ / DUTY
MENU
PRESET SEQ
I
LEVEL
VRANGE
RANGE
SW ON
+CV
MODE
LOAD
SET / VSET
LOCK
SHIFT
ABC
OPP / OCP