Basic Operation 5-19
4.
Select the voltage range.
Press the VRANGE (SHIFT+RANGE) key.
A voltage range pop-up menu appears.
Each time you press the VRANGE key, the voltage range switches
between 15 V and 150 V.
When the desired range is highlighted, stop pressing the key.
5.
Set the wattage value.
Check that the display is in the basic setting entry condition (the characters
“SET” is highlighted).
While viewing the display, turn the rotary knob.
First, use coarse adjustment to roughly set the value, and then switch to
fi
ne
adjustment to adjust the value precisely.
6.
Turn on the load.
Press the LOAD key.
The LOAD LED illuminates, and the current
fl
ows.
The display shows the measured values (voltage, current, and wattage)
at the load input terminal.
7.
Change the wattage setting.
Turn the rotary knob to change the wattage setting.
The wattage value cannot be set greater than the maximum value of the
selected range.
8.
Turn off the load.
Press the LOAD key.
The LOAD LED turns off, and the current is cut off.