PLZ-4W
Specifications 9-3
CR mode
*1 Conductance [S] = Input current [A]/input voltage [V] = 1/resistance [
Ω
]
*2 Converted value at the input current. At the sensing point. It is not applied for the condition of the parrallel operation.
*3 set = Vin/Rset
*4 Full scale of H range
*5 Vin: Input terminal voltage of Electronic Load
CV mode
*1 At the sensing point during remote sensing under the operating range of the input voltage. It is also applied for the
condition of the parrallel operation.
*2 With respect to a change in the current of 10 % to 100 % of the rating at an input voltage of 1.5 V (during remote
sensing).
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Operating range
*1
Range
H
22 S
– 400
μ
S
(45.455 m
Ω
– 2.5 k
Ω
)
44 S
– 800
μ
S
(22.727 m
Ω
– 1.25 k
Ω
)
133.332 S
– 2.4 mS
(7.5 m
Ω
– 416.666
Ω
)
22 S
– 400
μ
S
(45.455 m
Ω
– 2.5 k
Ω
)
88 S
– 1.6 mS
(11.363 m
Ω
– 625
Ω
)
M
2.2 S
– 40
μ
S
(454.55 m
Ω
– 25 k
Ω
)
4.4 S
– 80
μ
S
(227.27 m
Ω
– 12.5 k
Ω
)
13.3332 S
– 2420
μ
S
(75 m
Ω
– 4.1666 k
Ω
)
2.2 S
– 40
μ
S
(454.55 m
Ω
– 25 k
Ω
)
8.8 S
– 160
μ
S
(113.63 m
Ω
– 6.25 k
Ω
)
L
0.22 S
– 4
μ
S
(4.545 5
Ω
– 250 k
Ω
)
0.44 S
– 8
μ
S
(2.272 7
Ω
– 125 k
Ω
)
1.33332 S
– 24
μ
S
(750 m
Ω
– 41.666 k
Ω
)
0.22 S
– 4
μ
S
(4.545 5
Ω
– 250 k
Ω
)
0.88 S
– 16
μ
S
(1.136 3 m
Ω
– 62.5 k
Ω
)
Setting range
Range
H
23.1 S
– 0 S
(43.290 m
Ω
– OPEN)
46.2 S
– 0 S
(21.692 m
Ω
– OPEN)
139.9968 S
– 0 S
(7.1430 m
Ω
– OPEN)
23.1 S
– 0 S
(43.290 m
Ω
– OPEN)
92.4 S
– 0 S
(10.822 m
Ω
– OPEN)
M
2.31 S
– 0 S
(432.9 m
Ω
– OPEN)
4.62 S
– 0 S
(216.92 m
Ω
– OPEN)
13.99968 S
– 0 S
(71.430 m
Ω
– OPEN)
2.31 S
v0 S
(432.9 m
Ω
– OPEN)
9.24 S
– 0 S
(108.22 m
Ω
– OPEN)
L
0.231 S
– 0 S
(4.329
Ω
– OPEN)
0.462 S
– 0 S
(2.1692
Ω
– OPEN)
1.399968 S
v0 S
(714.30 m
Ω
– OPEN)
0.231 S
– 0 S
(4.329
Ω
– OPEN)
0.924 S
– 0 S
(1.0822
Ω
– OPEN)
Resolution
Range
H
400
μ
S
800
μ
S
2.424 mS
400
μ
S
1.6 mS
M
40
μ
S
80
μ
S
242.4
μ
S
40
μ
S
160
μ
S
L
4
μ
S
8
μ
S
24.24
μ
S
4
μ
S
16
μ
S
Accuracy of setting
*2
Range H, M
±
(0.5 % of set
*3
+ 0.5 % of f.s
*4
) + Vin
*5
/500 k
Ω
L
±
(0.5 % of set
*3
+ 0.5 % of f.s)
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Operating range
Range
H
1.5 V – 150 V
0 V – 150 V
L
1.5 V – 15 V
0 V – 15 V
Setting range
Range
H
0 V – 157.5 V
L
0 V – 15.75 V
Resolution
Range
H
10 mV
L
1 mV
Accuracy of setting
*1
Range H, L
±
(0.1 % of set + 0.1 % of f.s)
Input current variation
*2
12 mV