4-4 Names and Functions of Parts
PLZ-4W
4.2
Rear Panel
• Do not touch the load input terminal while the PLZ-4W is turned ON, as it
may lead to electric shock.
In addition, be sure to use the load input terminal cover.
• The load input terminals on the front and rear panels are coupled inside
the PLZ-4W. A voltage applied to one end will appear on the other end.
• Do not connect equipment to the load input terminals on the front and rear
panels simultaneously, as it cause damage.
• Avoid using the PLZ-4W in a dusty environment or an environment with
poor ventilation.
• Do not obstruct the air intake on the front panel and air exhaust on the rear
panel with objects. In particular, allow at least 20 cm of space behind the
PLZ-4W.
Fig. 4-2
Rear panel (PLZ164W)
WARNING
CAUTION
PROTECTIVE GROUNDING CONDUCTOR MUST
BE CONNECTED TO GROUND.
DO NOT REMOVE COVERS, REFER
SERVICING TO QUALIFIED PERSONNEL.
TO AVOID ELECTRIC SHOCK, THE POWER CORD
WARNING
USB
EXT CON
SH1 AH1 T6 L4 SR1 RL1 PP0 DC1 DT1 C0 E1
J1
RS232C
GPIB
AC INPUT
100-240V
47-63Hz
80VA MAX
DC INPUT
165W
1.5
-
150V
0
-
33A
[1] DC INPUT
[4] Remote sensing terminal
[7] RS232C
[6] GPIB
[8] USB
[3] AC INPUT
[5] Manufacturing number
[2] Air outlet
[9] J1/J2
[10] EXT CONT
EXT CON
J1
165W
1.5
-
150V
0
-
33A