PAN-A
4-3
Chap
.4
Applied Oper
ation
1
Fig.4-1
CONTROL terminal board
Connecting procedure
•
Never attempt to connect wires to the control terminals
while the POWER switch turned on. This may result in
electric shock or damage to the internal circuitry.
1. Turn off the OUTPUT switch.
2. Turn off the POWER switch.
S
S
1
2
7
8
13
14
19
Group A
Group A
Group B
Group B
Applicable wires
Group A (No. 2 to 19 terminals)
Single
wire:
φ
0.32 to
φ
0.65 (AWG28 to AWG22)
Twisted wire: 0.08 mm
2
to 0.32 mm
2
(AWG28 to AWG22)
Group B (-S, +S, and No. 1 terminals)
Single
wire:
φ
0.4 to
φ
1.2 (AWG26 to AWG16)
Twisted wire: 0.3 mm
2
to 1.25 mm
2
(AWG22 to AWG16)
(Bare
wire
diameter:
φ
0.18 or more)
S
S
2
7
8
13
14
19
PAN350-3.5A/
PAN600-2A (1000W model)
WARNING