PAN-A
4-35
Chap
.4
Applied Oper
ation
1
4.5
Master-slave-control series operation
It is possible to increase the output voltage by connecting several
slave units in series to one master unit. In a master-slave-control
series operation system, a preset output for all the units connected in
series can be designated only from the master unit.
• Master-slave-control series operation is not possible
on the PAN350-3.5A/PAN600-2A. If connected in
series, the unit may result in failure, electric shocks,
or
fi
res.
Number of units connectable in series:
The number of slave units to be connected in series is determined by
the rated output voltage and isolation voltage of each unit.
Taking the PAN35-10A as an example for series connection:
Since the rated output voltage is 35 V, and the isolation voltage is
±250 V, 250/35 = 7.1, i.e., up to 7 units including the master unit
can be connected in series.
The rated output voltage and the isolation voltage are described in
Chapter 7 "Speci
WARNING