6. Connect the master unit and slave units shown in Fig.4-22.
Fig.4-22 shows an example of how the rear output terminals are
connected in series for two slave units.
For the PAN16-50A user, see Fig. Fig.4-24.
When performing remote sensing in master-slave-control series
operation, see Fig.4-23.
To combine the PAN-A and PAN series, see Fig.4-25. When
remote sensing must be performed, see Fig.4-26.
• Use a load cable of suf
fi
cient current capacity to
cover the rated value.
• After series connection, mount the output terminal
cover (on the front or rear panel).
To mount the front auxiliary output terminal cover,
see "3.4 Mounting the auxiliary output terminal
cover".
• To assure good connection of load cables and control
wires, use crimped terminals.
• Position each unit with suf
fi
cient space around it. Do
not stack units a top one another.
• Connect any one of the + (pos.) and - (neg.) output
terminals to the
⊥
(chassis ground) terminal, using a
shorting bar.
7. Re-check that the connections and the switch settings are
correct.