PAN-A
6-5
Chap
.6
Maintenance
1
13. Using variable resistor "2", adjust the output voltage to 0 V.
Output voltage in full scale
14. Set the output voltage to the maximum.
For local control, turn the VOLTAGE control knob fully clock-
wise. For remote control, set the control signal to 10.5 V or 10
k
Ω
.
15. Using variable resistor "4", adjust the output voltage to 105
% of the rated output voltage.
• The maximum output voltage of the unit is speci
fi
ed
at 105 % of the rated output voltage. It is possible to
adjust to a level higher than 105 % using variable
resistor "4", but this may damage the unit.
• For remote control using external voltage, a 10 V control sig-
nal may be selected and adjusted to 100 % of the rated output
voltage of the unit.
Output voltage display in full scale
16. Adjust with variable resistor "5" so that the output voltage
indication of the unit equals the indication on the external
digital voltmeter (DVM) in a rated-voltage output condition.
Fig.6-3
Voltage system adjustment variable resistor
CAUTION
NOTE
2
4
5
6
7
8
S1
S2
S3
S4
S5
OVP
11
Front control panel
1
9
10
3
Output voltage offset
Output voltage in full scale
Output voltage
display in full scale
Never touch
"1", "3", "9" or "10".