PAN-A
6-3
Chap
.6
Maintenance
1
Voltage system adjustment procedure
The voltage system includes the following three items. Since all the
items are related to one another, adjust them all in the following pro-
cedure.
• Output voltage offset
• Output voltage in full scale
• Output voltage display in full scale
■
Connection of equipment
• To avoid electric shock, turn off the unit POWER
switch before making device connections.
1. Turn off the OUTPUT switch.
2. Turn off the POWER switch.
3. Check that the SENS switch is turned off.
If the SENS switch is turned on, it is impossible to adjust cor-
rectly.
4. Connect a DVM as shown in Fig.6-1.
For the PAN16-50A user, see Fig.6-2.
5. Connect the - (neg.) terminal and the chassis ground termi-
nal (
⊥
) with the shorting bar.
Fig.6-1
Connection for voltage system adjustment
WARNING
+
-
10A
Rear OUTPUT
terminal board
Front auxiliary output terminals
Crimped
terminal
Connect the shorting bar
to the - (neg.) terminal.
DVM
HI
LO