4-22
PAN-A
Fig.4-14
Connection and setup for output current con-
trol using external voltage
6. Re-check that the connections on the terminal board and
the switch settings are correct.
Before controlling output current using the external voltage, re-adjust
the current system of the unit. For the adjustment procedure, see "6.3
Adjustment".
2
7
8
13
14
19
1
2
3
4
5
6
7
8
9
10
S1
S2
S3
S4
S5
OVP
11
Rear OUTPUT terminal
board (PAN16-50A)
Rear CONTROL
terminal board
Rear OUTPUT
terminal board
Front control panel
Vext
[7]
[6]
Vext: external voltage source
0 ≤ Vext ≤ 10.5 [V]
Irtg: rated output current [A]
Set S3 to the upper position
and S4 to the lower position.
2-core shielded wire
or twisted-pair wire
Output current Io ≈
Irtg • Vext •
β
10
[A]