4-6
PAN-A
• For sensing wires, use wires with a higher voltage
rating than the isolation voltage of the unit. For
details, see "2.6 Output Terminal Isolation".
Protect the uncovered section of the shielded wire by
using insulation tubes with a withstand voltage
greater than the isolation voltage of the unit.
• To turn on/off the power supplied to a load using a
mechanical switch, provide additional switches
between the sensing wires as shown in Fig.4-7; turn
on/off the power and remote sensing function simul-
taneously. In addition, make sure the OUTPUT
switch or POWER switch turned off when turning on/
off the mechanical switch.
• If the sensing wires come loose, the output voltage
across the load cannot be stabilized and may cause
excessive voltage to be applied to the load. Securely
connect the sensing wires.
Fig.4-4
Remote sensing connection
WARNING
CAUTION
Crimped terminal
SENS
ON
OFF
Turn on
the switch.
S
S
1
+
S
−
S
Load
C
OUTPUT
terminal board
CONTROL terminal board
2-core shielded wire
Содержание PAN 110-1.5A