Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
9
Tools Required
•
Phillips Screwdriver
•
Level
1. To avoid scratching the
worksurface, place the top face
down onto a soft protective
surface.
2. Attach two leg sets to worksurface
bottom by aligning legs to
pre-drilled holes and inserting
three #12 x 1
3
/
4
” screws per leg
set (Figure 1).
Note:
When a worksurface will
be paired with a transitional
unit, a leg set with a shorter
transitional foot (Figure 2)
will be assembled to the end
of the worksurface where the
transitional unit attaches. Refer to
your space-planning layout.
3. Align modesty panel between leg
sets. Insert two #10 x ½” screws
per left and right side of modesty
panel into leg. Do not tighten at
this time (Figure 1).
4. Position the mounting bracket
of the power/data door over
the modesty panel holes that
correspond with worksurface
holes. Insert three #12 x 1”
screws through the mounting
bracket and modesty panel into
WorkZone
®
Desks - 24”, 30” x 30” through 54” Tops with Power & Data
Assembly Instructions
#10 x ½”
screw
power/data
door
modesty
panel
mounting
bracket
duplex
receptacle
#12 x 1"
screw
#1
worksurface
#12 x 1"
screw
door
clip
# 12 x 1"
screws
table-to-table
wireway
10-wire
harness
splice plate
adjustable
glide
leg set
adjustable
glide
Figure 1
#12 x 1" screw
#12 x
” screw
3
4
#10 x ½" screw
leg plug
4. Position the mounting bracket of the
power/data door over the modesty panel
holes that correspond with worksurface
holes. Insert three #12 x 1” screws through
the mounting bracket and modesty panel
into the worksurface. Tighten all screws to
secure the leg sets and modesty panel
(Figure 1).
5. Fasten door clips to the underside of the
worksurface with two #12 x 1” screws per
door clip (Figure 1).
Whenever tables are to be joined with
a table-to-table wireway and splice plate
(Figure 1), the vertical wire way (Figures 2 &
3) must be installed into the leg prior to the
table-to-table wireway being installed to the
worksurface. Refer now to step 9 and the
note before, if this is the case. Then return
back to step 6 below.
6. If worksurfaces will be ganged together,
attach table-to-table wireway to underside of
worksurface with two #12 x 1” screws on
ganging end(s). Also, attach splice plate to
worksurface with two #12 x 1” screws at
same end(s) (Figure 1).
All 10-wire harnesses must be
oriented the same direction to make proper
connections. At one end of each harness, on
the black connector near the clip, is an (N)
and arrow under the worksurface at the left
side, with the arrow pointing to the modesty
panel.
7. Correctly orient the 10-wire harness to the
underside of the worksurface with the arrow
pointing to the modesty panel as noted
above (Figure 1). Position 10-wire harness
to underside of worksurface over pre-drilled
mounting holes and attach with four #12 x
1” screws. Plug duplex receptacle into
power harness as illustrated. Secure
receptacle to power harness by sliding into
port until spring clips lock receptacle into
place (Figure 1).
Note:
Note:
Note:
If the position of the table requires
that the floor infeed be wired up at the
end of a run of worksurfaces, the
vertical wireway will be replaced by a
floor feed vertical wireway which is
explained in instructions 14 through 17.
8. Stand worksurface assembly right
side up and install two leg plugs into the
exposed holes at the outside of each leg
set as illustrated (Figure 3).
9.
a vertical wireway cap into the upper,
outside cut-out in each vertical wireway
where no table-to-table wireway is
installed (Figure 3).
Note:
Two different vertical wireway
halves are supplied with power & data
tables: The “vertical wireway - inner”
(with two cut-outs) is to be installed
facing the inside of the table (Figures 2
& 3). The “vertical wireway-outer, with
power/data” (single cut-out) (Figures 2
& 3) is to be installed on the outside of a
leg, and the cut-out must face the
underside of the table. Whenever a
”table-to-table wireway” is installed
between tables (Figure 2), the vertical
wireways must be installed to the leg set
before the table-to-table wireway is
installed.
Vertical wireways fasten into each
other from each side of the leg set
opening and must be oriented correctly
to press together. Begin by positioning
an “outer vertical wireway” (one cut-
out), to the outside of the leg set as
illustrated with the cut-out facing the
worksurface. Next position the inner
wireway cover (two cut-outs) in the
correct orientation at the inside of the
leg set and press it into the outer.
Press
WorkZone with Power & Data - Assembly Instructions
vertical wireway-outer
with power/data
(single cut-out)
transitional
leg
splice
plate
vertical wireway-inner
(two cut-outs)
Figure 2
table-to-table
wireway
leg plug
vertical
wireway cap
leg set
adjustable
glide
Figure 3
power & data
module
vertical
wireway-outer
(end-of-run)
vertical
wireway-inner
worksurface
grommet cover
Figure 2
the worksurface. Tighten all
screws to secure the leg sets and
modesty panel (Figure 1).
5. Fasten door clips to the underside
of the worksurface with two
#12 x 1” screws per door clip
(Figure 1).
Note:
Whenever tables are to
be joined with a table-to-table
wireway and splice plate (Figures
1 & 2), the vertical wire way
(Figures 2 & 3) must be installed
into the leg prior to the
table-to-table wireway being
installed to the worksurface. Refer
now to step 9 and the note before,
if this is the case. Then return
back to step 6 below.
6. If worksurfaces will be ganged
together, attach
table-to-table wireway to
underside of worksurface with
two #12 x 1” screws on ganging
end(s). Also, attach splice plate
to worksurface with two #12 x 1”
screws at same end(s)
(Figures 1 & 2).
Note:
All 10-wire harnesses
must be oriented the same
direction to make proper
connections. At one end of each
harness, on the black connector
near the clip, is an (N) and arrow
under the worksurface at the left
side, with the arrow pointing to
the modesty panel.
7. Correctly orient the 10-wire
harness to the underside of
the worksurface with the arrow
pointing to the modesty panel as
noted above (Figure 1). Position
10-wire harness to underside
of worksurface over pre-drilled
mounting holes and attach with
four #12 x 1” screws. Plug duplex
receptacle into power harness
as illustrated. Secure receptacle
to power harness by sliding
into port until spring clips lock
receptacle into place (Figure 1).
WARNING:
Assembly of all mechanical
frame components must be completed
before making any electrical connections.
All electrically connected furnishings must
also be mechanically connected.