14
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
8. Stand worksurface assembly
right side up and install two leg
plugs into the exposed holes at
the outside of each leg set as
illustrated (Figure 3).
Note:
Two different vertical
wireway halves are supplied with
power & data tables: The “vertical
wireway - inner” (with two
cut-outs) is to be installed facing
the inside of the table (Figures 2
& 3). The “vertical wireway-outer,
with power/data” (single cut-out)
(Figures 2 & 3) is to be installed
on the outside of a leg, and the
cut-out must face the underside
of the table. Whenever a
”table-to-table wireway” is
installed (Figure 2), the vertical
wireways must be installed to the
leg set before the table-to-table
wireway is installed.
9. Vertical wireways fasten into each
other from each side of the leg
set opening and must be oriented
correctly to press together.
Begin by first positioning an
“outer vertical wireway” (single
cut-out), to the outside of the leg
set as illustrated, with cut-out
closest to worksurface. Next
position the inner wireway cover
(two cut-outs) in the correct
orientation at the inside of the
leg set and press it into the outer
wireway (Figures 2 & 3). For
end-of run tables, press a vertical
wireway cap into the upper,
outside cut-out in each vertical
wireway where no table-to-table
wireway is installed (Figure 3).
10. If worksurface assemblies are to
be ganged, attach them together
with #12 x 1” screws at table-to-
table wireway and splice plate.
Do not tighten at this time.
11. Level worksurface by turning
four adjustable glides either in
or out. The jambnuts between
the glides and the bottom of
the leg sets must be tightened
up against the bottom of the leg
to secure the adjustable glides
(Figure 3). Tighten screws that
gang worksurfaces at this time.
12. Press worksurface grommets into
wireway holes in worksurface top
(Figure 3). Route the power and
data module cord through the
power and data module hole in
the worksurface. Snap the power
and data module into the module
hole (Figure 3). From under the
worksurface, with the power/data
door opened, plug the power cord
into the duplex receptacle on the
10-wire harness. Check for proper
operation of the power and data
module. To open module push
down on the module and it will
pop-up. To close, press downward
and it will snap closed.
WorkZone
®
Desks - 24”, 30” x 60”, 66” & 72” Tops with Power & Data
Assembly Instructions
4. Position the mounting bracket of the
power/data door over the modesty panel
holes that correspond with worksurface
holes. Insert three #12 x 1” screws through
the mounting bracket and modesty panel
into the worksurface. Tighten all screws to
secure the leg sets and modesty panel
(Figure 1).
5. Fasten door clips to the underside of the
worksurface with two #12 x 1” screws per
door clip (Figure 1).
6. If worksurfaces will be ganged together,
attach table-to-table wireway to underside of
worksurface with two #12 x 1” screws on
ganging end(s). Also, attach splice plate to
worksurface with two #12 x 1” screws at
same end(s) (Figure 1).
All 10-wire harnesses must be
oriented the same direction to make proper
connections. At one end of each harness, on
the black connector near the clip, is an (N)
and arrow under the worksurface at the left
side, with the arrow pointing to the modesty
panel.
7. Correctly orient the two 10-wire
harnesses to the underside of the
worksurface with the arrows pointing to the
modesty panel as noted above (Figure 1).
Position the 10-wire harnesses
.
Plug duplex receptacle into power harness
as illustrated. Secure receptacle to power
harness by sliding into port until spring clips
lock receptacle into place (Figure 1)
Note:
Whenever tables are to be joined with
a table-to-table wireway and splice plate
(Figures 1 & 2 ), the inner and outer vertical
wireway sections must be installed into the
leg prior to installing the table-to-table
wireway to the worksurface. Refer now to
the “Note” and step 9 if this is the case.
Then return back to step 6 below.
to underside
of worksurface over pre-drilled mounting
holes and attach with four #12 x 1” screws
Note:
.
Note:
If the position of the table requires that
the floor infeed be wired up at the end of a
run of worksurfaces, the vertical wireway
will be replaced by a floor feed vertical
wireway which is explained in instructions
14 through 17.
8. Stand worksurface assembly right side up
and install two leg plugs into the exposed
holes at the outside of each leg set as
illustrated (Figure 3).
Note:
Two different vertical wireway halves
are supplied with power & data tables: The
“vertical wireway - inner” (with two cut-
outs) is to be installed facing the inside of
the table (Figures 2 & 3). The “vertical
wireway-outer, with power/data” (single cut-
out) (Figures 2 & 3) is to be installed on the
outside of a leg, and the cut-out must face
the underside of the table. Whenever a
”table-to-table wireway” is installed (Figure
2), the vertical wireways must be installed to
the leg set before the table-to-table wireway
is installed.
9. Vertical wireways fasten into each other
from each side of the leg set opening and
must be oriented correctly to press together.
Begin by first positioning an “outer vertical
wireway” (single cut-out), to the outside of
the leg set as illustrated, with cut-out closest
to worksurface. Next position the inner
wireway cover (two cut-outs) in the correct
orientation at the inside of the leg set and
press it into the outer wireway (Figures 2 &
3). For end-of run tables, press a vertical
wireway cap into the upper, outside cut-out
in each vertical wireway where no table-to-
table wireway is installed (Figure 3).
WorkZone with Power & Data - Assembly Instructions
vertical wireway-outer
with power/data
(single cut-out)
transitional
leg
splice
plate
vertical wireway-inner
(two cut-outs)
Figure 2
table-to-table
wireway
leg plug
vertical
wireway cap
leg set
adjustable
glide
Figure 3
power & data
module
vertical
wireway-outer
(end-of-run)
vertical
wireway-inner
worksurface
grommet cover
power and
data module
Figure 3