Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
13
Tools Required
•
Phillips Screwdriver
•
Level
1. To avoid scratching the
worksurface, place the top face
down onto a soft protective
surface.
2. Attach two leg sets to worksurface
bottom by aligning legs to
pre-drilled holes and inserting
three #12 x 1
3
/
4
” screws per leg
set (Figure 1).
Note:
In the instance where a
worksurface is to be paired with
a transitional unit, a leg set with
a short transitional foot (Figure
2) will be assembled to the end
of the worksurface where the
transitional unit is to be attached.
Refer to your space-planning
layout.
3. Align modesty panel between leg
sets. Insert two #10 x ½” screws
per left and right side of modesty
panel into leg. Do not tighten at
this time (Figure 1).
4. Position the mounting bracket
of the power/data door over
the modesty panel holes that
correspond with worksurface
holes. Insert three #12 x 1”
screws through the mounting
bracket and modesty panel into
the worksurface. Tighten all
screws to secure the leg sets and
modesty panel (Figure 1).
WorkZone
®
Desks - 24”, 30” x 60”, 66” & 72” Tops with Power & Data
Assembly Instructions
#10 x ½"
screw
modesty
panel
mounting
bracket
duplex
receptacle
power/data
door
#12 x 1"
screw
worksurface
#12 x 1"
screw
door
clip
# 12 x 1"
screws
table-to-table
wireway
jumper cable
10-wire
harnesses
splice plate
Figure1
leg set
adjustable
glide
adjustable
glide
Figure 1
#12 x 1" screw
#12 x
” screw
3
4
#10 x ½" screw
leg plug
4. Position the mounting bracket of the
power/data door over the modesty panel
holes that correspond with worksurface
holes. Insert three #12 x 1” screws through
the mounting bracket and modesty panel
into the worksurface. Tighten all screws to
secure the leg sets and modesty panel
(Figure 1).
5. Fasten door clips to the underside of the
worksurface with two #12 x 1” screws per
door clip (Figure 1).
6. If worksurfaces will be ganged together,
attach table-to-table wireway to underside of
worksurface with two #12 x 1” screws on
ganging end(s). Also, attach splice plate to
worksurface with two #12 x 1” screws at
same end(s) (Figure 1).
All 10-wire harnesses must be
oriented the same direction to make proper
connections. At one end of each harness, on
the black connector near the clip, is an (N)
and arrow under the worksurface at the left
side, with the arrow pointing to the modesty
panel.
7. Correctly orient the two 10-wire
harnesses to the underside of the
worksurface with the arrows pointing to the
modesty panel as noted above (Figure 1).
Position the 10-wire harnesses
.
Plug duplex receptacle into power harness
as illustrated. Secure receptacle to power
harness by sliding into port until spring clips
lock receptacle into place (Figure 1)
Note:
Whenever tables are to be joined with
a table-to-table wireway and splice plate
(Figures 1 & 2 ), the inner and outer vertical
wireway sections must be installed into the
leg prior to installing the table-to-table
wireway to the worksurface. Refer now to
the “Note” and step 9 if this is the case.
Then return back to step 6 below.
to underside
of worksurface over pre-drilled mounting
holes and attach with four #12 x 1” screws
Note:
.
Note:
If the position of the table requires that
the floor infeed be wired up at the end of a
run of worksurfaces, the vertical wireway
will be replaced by a floor feed vertical
wireway which is explained in instructions
14 through 17.
8. Stand worksurface assembly right side up
and install two leg plugs into the exposed
holes at the outside of each leg set as
illustrated (Figure 3).
Note:
Two different vertical wireway halves
are supplied with power & data tables: The
“vertical wireway - inner” (with two cut-
outs) is to be installed facing the inside of
the table (Figures 2 & 3). The “vertical
wireway-outer, with power/data” (single cut-
out) (Figures 2 & 3) is to be installed on the
outside of a leg, and the cut-out must face
the underside of the table. Whenever a
”table-to-table wireway” is installed (Figure
2), the vertical wireways must be installed to
the leg set before the table-to-table wireway
is installed.
9. Vertical wireways fasten into each other
from each side of the leg set opening and
must be oriented correctly to press together.
Begin by first positioning an “outer vertical
wireway” (single cut-out), to the outside of
the leg set as illustrated, with cut-out closest
to worksurface. Next position the inner
wireway cover (two cut-outs) in the correct
orientation at the inside of the leg set and
press it into the outer wireway (Figures 2 &
3). For end-of run tables, press a vertical
wireway cap into the upper, outside cut-out
in each vertical wireway where no table-to-
table wireway is installed (Figure 3).
WorkZone with Power & Data - Assembly Instructions
vertical wireway-outer
with power/data
(single cut-out)
transitional
leg
splice
plate
vertical wireway-inner
(two cut-outs)
Figure 2
table-to-table
wireway
leg plug
vertical
wireway cap
leg set
adjustable
glide
Figure 3
power & data
module
vertical
wireway-outer
(end-of-run)
vertical
wireway-inner
worksurface
grommet cover
Figure 2
5. Fasten door clips to the underside
of the worksurface with two
#12 x 1” screws per door clip
(Figure 1).
Note:
Whenever tables are to
be joined with a table-to-table
wireway and splice plate (Figures
1 & 2 ), the inner and outer
vertical wireway sections must
be installed into the leg prior
to installing the table-to-table
wireway to the worksurface. Refer
now to the “Note” and step 9 if
this is the case. Then return back
to step 6 below.
6. If worksurfaces will be ganged
together, attach table-to-
table wireway to underside of
worksurface with two #12 x 1”
screws on ganging end(s). Also,
attach splice plate to worksurface
with two #12 x 1” screws at same
end(s) (Figures 1 & 2).
Note:
All 10-wire harnesses
must be oriented the same
direction to make proper
connections. At one end of each
harness, on the black connector
near the clip, is an (N) and arrow
under the worksurface at the left
side, with the arrow pointing to
the modesty panel.
7. Correctly orient the two 10-wire
harnesses to the underside of
the worksurface with the arrows
pointing to the modesty panel
as noted above (Figure 1).
Position the 10-wire harnesses
to underside of worksurface over
pre-drilled mounting holes and
attach with four #12 x 1” screws.
Plug duplex receptacle into power
harness as illustrated. Secure
receptacle to power harness by
sliding into port until spring
clips lock receptacle into place
(Figure 1).
Note:
If the position
of the table requires that the floor
infeed be wired up at the end of a
run of worksurfaces, the vertical
wireway will be replaced by a
floor feed vertical wireway which
is explained in instructions 14
through 17.
WARNING:
Assembly of all mechanical
frame components must be completed
before making any electrical connections.
All electrically connected furnishings must
also be mechanically connected.