138 Keysight E8357D/67D & E8663D PSG User’s Guide
Basic Digital Operation
Using Waveform Clipping
2.
Press
Mode
>
Dual ARB
>
Select Waveform
and ensure that
AUTOGEN_WAVEFORM
is highlighted on the display. AUTOGEN_WAVEFORM
is the default name assigned to the waveform you generated in the
previous step.
3.
Press
Select Waveform
. This selects the waveform and returns you to the
previous softkey menu.
4.
Press
ARB Off On
to On. The Dual Arb player must be turned on to display
the CCDF plot in the following steps.
5.
Press
ARB Setup
>
Waveform Utilities
>
Waveform Statistics
and ensure
that
AUTOGEN_WAVEFORM
is highlighted on the display.
6.
Press
CCDF Plot
and observe the position of the waveform’s curve, which
is the darkest line.
7.
Press
Return
>
Return
>
Clipping
.
8.
Ensure that the
Clipping Type |I+jQ| |I|,|Q|
softkey is set to
|I+jQ|
, which is
circular clipping.
9.
Press
Clip |I+jQ| To
>
80
>
%
>
Apply to Waveform
. The I and Q data are
both clipped by 80%. Once clipping is applied to the waveform it cannot
be undone. Repeated use of the clipping function has a cumulative effect
on the waveform.
10.
Press
Waveform Statistics
>
CCDF Plot
and observe the waveform’s curve.
Notice the reduction in peak–to–average power, relative to the previous
plot, after applying clipping.
Configuring Rectangular Clipping
This procedure shows you how to configure rectangular clipping. The
rectangular setting clips the I and Q data independently. For more information
about rectangular clipping, refer to
“How Clipping Reduces Peak–to–Average
.
1.
Press
Preset
>
Mode
>
Custom
>
Arb Waveform Generator
>
Digital
Modulation Off On
to On. This generates a custom arbitrary waveform for
use in this procedure. You can also use a previously stored or downloaded
waveform.
2.
Press
Mode
>
Dual ARB
>
Select Waveform
and ensure that
AUTOGEN_WAVEFORM
is highlighted on the display. AUTOGEN_WAVEFORM
is the default name assigned to the waveform you generated in the
previous step.
3.
Press
Select Waveform
. This selects the waveform and returns you to the
previous softkey menu.
4.
Press
ARB Off On
to On. The Dual Arb player must be turned on to display
the CCDF plot in the following steps.
Содержание E8663D
Страница 4: ...4...
Страница 58: ...44 Keysight E8357D 67D E8663D PSG User s Guide Signal Generator Overview Rear Panel...
Страница 186: ...172 Keysight E8357D 67D E8663D PSG User s Guide Optimizing Performance Wideband IQ FM Mode 3 2 GHz Option 018...
Страница 198: ...184 Keysight E8357D 67D E8663D PSG User s Guide Analog Modulation Configuring the LF Output Option UNT...
Страница 212: ...198 Keysight E8357D 67D E8663D PSG User s Guide Custom Arb Waveform Generator Working with Filters...
Страница 226: ...212 Keysight E8357D 67D E8663D PSG User s Guide Custom Arb Waveform Generator Configuring Hardware...
Страница 286: ...272 Keysight E8357D 67D E8663D PSG User s Guide AWGN Waveform Generator Configuring the AWGN Generator...
Страница 326: ...312 Keysight E8357D 67D E8663D PSG User s Guide Peripheral Devices Millimeter Wave Source Modules...
Страница 346: ...332 Keysight E8357D 67D E8663D PSG User s Guide Troubleshooting Returning a Signal Generator to Keysight Technologies...