94 Keysight E8357D/67D & E8663D PSG User’s Guide
Basic Digital Operation
Arbitrary (ARB) Waveform File Headers
NOTE
If a setting is unspecified in the file header, the signal generator’s current
value for that setting does not change when you select and play the
waveform in the future.
The
Current Inst. Settings
column shows the current signal
generator settings for the active modulation. These settings become the
saved header settings when they are saved to the file header (as
Figure 3-2
Custom Digital Modulation Default Header Display
2.
Save the information in the
Current Inst. Settings
column to the file
header:
Press
Save Setup To Header
.
Both the
Saved Header Settings
column and the
Current Inst.
Settings
column now display the same settings; the
Saved Header
Settings
column lists the settings saved in the file header.
The file header contains the following signal generator settings:
Lets you enter/edit the
Description field
Clears the Saved Header
Settings column to the
default settings
Saves the Current Inst. Settings
column to the Saved Header
Settings column
Current signal generator
settings
Page 1
Default Header Settings
Note
:
Parameters that are inactive (such as
Runtime Scaling) can be set only in
the dual ARB player.
Page 2
32–Character
Description:
A description entered for the header, such as a the waveform’s function (saved/edited with the
Edit Description
Sample Rate:
The ARB sample clock rate.
Runtime Scaling:
The Runtime scaling value. Runtime scaling is applied in real–time while the waveform is playing.
This setting can be changed only for files in the dual ARB player.
Marker 1...4 Polarity:
The marker polarity, positive or negative (described on
).
ALC Hold Routing:
Which marker, if any, implements the PSG’s ALC hold function (described on
RF Blank Routing:
Which marker, if any, implements the PSG’s RF blanking function (described on
).
Содержание E8663D
Страница 4: ...4...
Страница 58: ...44 Keysight E8357D 67D E8663D PSG User s Guide Signal Generator Overview Rear Panel...
Страница 186: ...172 Keysight E8357D 67D E8663D PSG User s Guide Optimizing Performance Wideband IQ FM Mode 3 2 GHz Option 018...
Страница 198: ...184 Keysight E8357D 67D E8663D PSG User s Guide Analog Modulation Configuring the LF Output Option UNT...
Страница 212: ...198 Keysight E8357D 67D E8663D PSG User s Guide Custom Arb Waveform Generator Working with Filters...
Страница 226: ...212 Keysight E8357D 67D E8663D PSG User s Guide Custom Arb Waveform Generator Configuring Hardware...
Страница 286: ...272 Keysight E8357D 67D E8663D PSG User s Guide AWGN Waveform Generator Configuring the AWGN Generator...
Страница 326: ...312 Keysight E8357D 67D E8663D PSG User s Guide Peripheral Devices Millimeter Wave Source Modules...
Страница 346: ...332 Keysight E8357D 67D E8663D PSG User s Guide Troubleshooting Returning a Signal Generator to Keysight Technologies...