BOP HIPWR 080709
TABLE 2-1. REAR PANEL CONNECTOR FUNCTIONS
NUMBER
(FIGURE 2-1)
CONNECTOR/TERMINAL
(REFERENCE DESIGNATOR)
FUNCTION
1
IEEE 1118 (BITBUS)
PORT(1)
(connector A1J4)
Used for multiple identical BOP master/slave parallel, and series and series-parallel
configurations (refer to PAR. 2.8, see Table 2-2).
2
TRIGGER
(connector A1J3)
May be used to initiate BOP output. (See Table 2-3.)
3
IEEE 488 (GPIB) PORT
(connector A1J6)
Used for Remote control of the BOP via the IEEE 488 (GPIB) interface (See Table
2-11.)
4
ANALOG I/O PORT
(connector A2A5J6)
Provides interface for analog input/output signals. (See Table 2-10.)
5
PARALLEL/SERIAL
CONTROL PORT
(connectors A2A5J3, IN
and A2A5J4, OUT)
Provides interconnections used to control parallel or serial configurations of identi-
cal BOP’s as a single power supply (see Table 2-7 for A2A5J3, IN and Table 2-6 for
A2A5J4, OUT).
6
PARALLEL/SERIAL
PROTECT PORT
(connectors A2A5J1, IN
and A2A5J2 OUT)
Provides interconnections used to control protection shutdown of power supplies
connected in parallel or serial configurations (see Table 2-8 for A2A5J1, IN and
Table 2-9 for A2A5J2, OUT).
7
EXT PROTECT PORT
(connector A2A5J7)
Provides means for controlling protection via external circuitry and provides status
flags to external circuitry. (See Table 2-4.)
8
INPUT connector
(connector A7J1)
Connects source power to unit.
Pin 1 - Line (or Line 1 without Neutral connection)
Pin 2 - Neutral (or Line 2 without Neutral connection)
Pin 3 - Ground (Protective conductor terminal)
9
Monitor and Sensing
terminal block
(terminal block A7A1TB1)
Terminal block provides external connections as follows:
OUT S: Sense line connection to load (compensate for voltage drop on connections
to load.) See PAR. 2.5.6 and 2.5.7 (Terminal 2).
OUT MON: Monitor connection used to monitor output voltage at power terminals
and to implement local sensing (Terminal 3).
GND NET: Grounding network connection (Terminal 4). See PAR. 2.5.3.1.
GND: Chassis ground connection (Terminal 5).
COM MON: Monitor return connection (Terminal 6). Used to monitor output voltage
at power terminals and to implement local sensing.
COM S: Sense line return connection from load (Terminal 7) See PAR. 2.5.6 and
2.5.7
10
terminals
Frame or chassis terminals
11
COMMON
(terminal A7J3)
Power output return from load.
12
OUTPUT
(terminal A7J2)
Power output connection to load.
13
RS232 PORT
(connector A1J5)
Used for Remote control of the BOP via the RS 232 serial interface. (See Table 2-5
for details.)
Содержание BOP 1000W
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 31: ......
Страница 32: ......
Страница 36: ......
Страница 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 61: ...FIGURE 2 11 POWER ON DEFAULT SCREEN FOR SLAVE UNIT 2 8 4 OPERATING INSTRUCTIONS FOR MULTIPLE UNIT COMBINATIONS...
Страница 63: ...080709 C 25 FIGURE 2 12 3 X 2 3 SERIES X 2 PARALLEL CONFIGURA TION LOCAL SENSING TYPICAL 2 25 2 26 Blank 24 25...
Страница 64: ......
Страница 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Страница 125: ......
Страница 128: ......