B-32
BOP-1K 080709
B.126 SYSTem:COMMunication:SERial:PACE COMMAND
SYST:COMM:SER:PACE
Syntax
:
Short Form: SYST:COMM:SER:PACE {NONE | XON}
Long Form: SYSTem:COMMunication:SERial:PACE {NONE | XON}
Description:
Enables (XON) or disables (NONE) data flow control via the serial interface
(
see PAR. 3.5.6.2.1).
See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.127 SYSTem:COMMunication:SERial:PACE? QUERY
SYST:COMM:SER:PACE?
Syntax
:
Short Form: SYST:COMM:SER:PACE?
Long Form: SYSTem:COMMunication:SERial:PACE?
Return Value: {01 | 00}
Description:
Returns 01 when data flow control via the serial interface is enabled (XON) or 00 when disabled
(NONE)
(see PAR. 3.5.6.2.1).
B.128SYSTem:COMMunication:SERiaL:PROMpt COMMAND
SYST:COMM:SER:PROM
Syntax
:
Short Form: SYST:COMM:SER:PROM {ON | OFF} or {0 | 1}
Long Form: SYSTem:COMMunication:SERial:PROMpt {ON | OFF} or {0 | 1}
Description:
Enables (1 or ON) or disables (0 or OFF) prompt
(see PAR. 3.5.6.2.3). Sending 1 or ON causes the
unit to return > character after the command is parsed. See PAR. 3.5.2.2 and Figure 3-16 for special
programming considerations.
B.129 SYSTem:COMMunication:SERial:PROMpt? QUERY
SYST:COMM:SER:PROM?
Syntax
:
Short Form: SYST:COMM:SER:PROM?
Long Form: SYSTem:COMMunication:SERial:PROMpt?
Return Value: {1 | 0}
Description:
Returns 1 when prompt is enabled (ON) or 0 when disabled (OFF).
(See PAR. 3.5.6.2.3.)
B.130 SYSTem:ERRor? QUERY
SYST:ERR?
Syntax:
Short Form: SYST:ERR?
Long Form: SYSTem:ERRor?
Return Value:
<int_value,string>
Description:
Posts error messages to the output queue.
Returns the next error number followed by its corre-
sponding error message string from the instrument error queue. The error queue is a FIFO (first in first
out) buffer that stores errors as they occur. As it is read, each error is removed from the queue and the
next error message is made available. When all errors have been read, the query returns 0,"No error".
If more errors are accumulated than the queue can hold, it will overflow. The oldest errors stay in the
queue but the most recent errors are discarded. The last error in the queue will be -350,"Queue Over-
flow." Error messages are defined in Table B-5.
B.131 SYSTem:ERRor:CODE? QUERY
SYST:ERR:CODE?
Syntax
:
Short Form: SYST:ERR:CODE?]
Long Form: SYSTem:ERRor:CODE?
Description: Returns the three character error code without the ASCII definition string. The error codes are defined
in table B-5 (See example, Figure B-12.)
B.132 SYSTem:ERRor:CODE:ALL? QUERY
SYST:ERR:CODE:ALL?
Syntax
:
Short Form: SYST:ERR:CODE:ALL?]
Long Form: SYSTem:ERRor:CODE:ALL?
Return Value:
Description: Returns a comma-separated list of all error codes. A maximum of 31 codes will be returned; if the
queue is empty, the power supply returns 0.
B.133 SYSTem:KEYBoard COMMAND
SYST:KEYB
Syntax:
Short Form: SYST:KEYB [DIS | ENAB]
Long Form: SYSTem:KEYBoard [DISable | ENABle]
Description: Locks (DIS) or unlocks (ENAB) the front panel keypad..
Содержание BOP 1000W
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 31: ......
Страница 32: ......
Страница 36: ......
Страница 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 61: ...FIGURE 2 11 POWER ON DEFAULT SCREEN FOR SLAVE UNIT 2 8 4 OPERATING INSTRUCTIONS FOR MULTIPLE UNIT COMBINATIONS...
Страница 63: ...080709 C 25 FIGURE 2 12 3 X 2 3 SERIES X 2 PARALLEL CONFIGURA TION LOCAL SENSING TYPICAL 2 25 2 26 Blank 24 25...
Страница 64: ......
Страница 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Страница 125: ......
Страница 128: ......