Series 2600 System SourceMeters Reference Manual
Digital I/O Port 10-5
Return to
2600S-901-01 Rev. A / May 2006
Figure 10-2
Digital I/O port configuration
DIGITAL I/O INTERFACE (All Series 2600 Models):
Connector: 25-pin female D
Input/Output pins: 14 open-drain I/O bits
Absolute maximum input voltage: 5.25V
Absolute minimum input voltage: -0.25V
Maximum logic low input voltage: 0.7V @ +850
m
A
Minimum logic high input voltage: 2.1V @ +570
m
A
Maximum source current (flowing out of digital I/O bit): +960
m
A
Absolute Maximum sink current (flowing into digital I/O bit): -11.0A
Maximum Sink Current @ Maximum Logic Low Voltage (0.7V): -5.0mA.
Read by firmware
5.1k
W
Rear panel
100
W
Written by firmware
+5VD
600mA solid state
fuse
DIGITAL I/O pin
(on DIGITAL I/O connector)
GND pin
(on DIGITAL I/O connector)
+5V pin
(on DIGITAL I/O connector)