IEEE-488 Reference
3-57
Table 3-15
Trigger command summary
Command
Description
Default
parameter
SCPI
Ref.
:INITiate
[:IMMediate]
:CONTinuous <b>
:CONTinuous?
:POFLag <name>
:POFLag?
:ABORt
:ARM[:SEQuence[1]]
[:LAYer[1]]
:IMMediate
:COUNt <n>
:COUNt?
:SOURce <name>
:SOURce?
:SIGNal
:TCONfigure
:DIRection <name>
:DIRection?
:ASYNchronous
:ILINe <NRf>
:ILINe?
:OLINe <NRf>
:OLINe?
:RTCLock
:DATE <yr>, <mo>, <day>
:DATE?
:TIME <hr>, <min>, <sec>
:TIME?
:LAYer2
:IMMediate
:COUNt <n>
:COUNt?
:DELay <n>
:DELay?
:SOURce <name>
:SOURce?
:TIMer <n>
:TIMer?
:SIGNal
:TCONfigure
:DIRection <name>
:DIRection?
:ASYNchronous
:ILINe <NRf>
:ILINe?
:OLINe <NRf>
:OLINe?
Subsystem command path:
Initiate one trigger cycle.
Enable or disable continuous initiation.
Query continuous initiation.
INCLude or EXCLude no pending flag for initiate com-
mands
Query pending operation flag.
Reset trigger system.
Path to configure arm layers:
Path to program Arm Layer 1:
Loop around control source.
Specify arm count (1 to 99999, or INF).
Query arm count.
Select control source (HOLD, IMMediate, RTCLock,
MANual, BUS, TLINk or EXTernal).
Query control source.
Loop around control source.
Path to configure Triggers:
Enable (SOURce) or disable (ACCeptor).
Query direction.
Path to configure asynchronous Trigger Link:
Select input line (1 to 6).
Query input line.
Select output line (1 to 6).
Query output line.
Path to configure the RTCLock control source:
Specify the date for the clock event.
Query the date for the clock event.
Specify the time for the clock event.
Query the time for the clock event.
Path to program Arm Layer 2:
Loop around control source.
Specify scan count (1 to 99999 or INF).
Query scan count.
Program delay (0 to 999999.999 sec)
Query delay.
Select control source (HOLD, IMMediate, TIMer,
MANual, BUS, TLINk or EXTernal).
Query control source.
Set timer interval (0 to 999999.999 sec).
Query timer.
Loop around control source.
Path to configure Triggers:
Enable (SOURce) or disable (ACCeptor) Bypass.
Query direction.
Path to configure asynchronous Trigger Link:
Select input line (1 to 6).
Query input line.
Select output line (1 to 6).
Query output line.
(Note 1)
INCLude
1
IMMediate
ACCeptor
2
1
(Note 3)
0
IMMediate
0.1
ACCeptor
2
1
√
√
√
√
√
√
√
√
√
√
(Note 2)
√
√
√
√
√
√
√
√
(Note 2)
√
√
√
√
3.24.1
3.24.2
3.24.3
3.24.4
3.24.6
3.24.8
3.24.9
3.24.10
3.24.3
3.24.4
3.24.5
3.24.6
3.24.7
3.24.8
3.24.9
Содержание 6517A
Страница 1: ...Model 6517A Electrometer User s Manual A G R E A T E R M E A S U R E O F C O N F I D E N C E...
Страница 310: ...A Specifications...
Страница 311: ...A Specifications...