Front Panel Operation
2-6
Table 2-5
Status and error messages
Number
Description
Event
-440
-430
-420
-410
-350
“Query UNTERMINATED after
indefinite response”
“Query DEADLOCKED”
“Query UNTERMINATED”
“Query INTERRUPTED”
“Queue overflow”
EE
EE
EE
EE
EE
-330
-314
-285
-284
-282
-281
“Self Test failed”
“Save/recall memory lost”
“Program syntax error”
“Program currently running”
“Illegal program name”
“Cannot create program”
EE
EE
EE
EE
EE
EE
-260
-241
-230
-224
-223
-222
“Expression Error”
“Hardware missing”
“Data corrupt or stale”
“Illegal parameter value”
“Too much data”
“Parameter data out of range”
EE
EE
EE
EE
EE
EE
-221
-220
-215
-214
-213
“Settings conflict”
“Parameter Error”
“Arm deadlock”
“Trigger deadlock”
“Init ignored”
EE
EE
EE
EE
EE
-212
-211
-210
-202
-201
“Arm ignored”
“Trigger ignored”
“Trigger error”
“Settings lost due to rtl”
“Invalid while in local”
EE
EE
EE
EE
EE
-200
-178
-171
-170
-168
“Execution error”
“Expression data not allowed”
“Invalid expression”
“Expression error”
“Block data not allowed”
EE
EE
EE
EE
EE
-161
-160
-158
-154
-151
“Invalid block data”
“Block data error”
“String data not allowed”
“String too long”
“Invalid string data”
EE
EE
EE
EE
EE
-150
-148
-144
-141
-140
“String data error”
“Character data not allowed”
“Character data too long”
“Invalid character data”
“Character data error”
EE
EE
EE
EE
EE
-128
-124
-123
“Numeric data not allowed”
“Too many digits in number”
“Exponent too large”
EE
EE
EE
-121
-120
“Invalid character in number”
“Numeric data error”
EE
EE
-114
-113
-112
-111
-110
“Header suffix out of range”
“Undefined header”
“Program mnemonic too long”
“Command Header Separator Error”
“Command Header Error”
EE
EE
EE
EE
EE
-109
-108
-105
-104
-103
“Missing Parameter”
“Parameter not allowed”
“GET not allowed.”
“Data Type Error”
“Invalid Separator”
EE
EE
EE
EE
EE
-102
-101
-100
“Syntax Error”
“Invalid Character”
“Command Error”
EE
EE
EE
000
“No Error”
SE
+101
+121
+122
+123
+124
+125
“Operation Complete”
“Device calibrating”
“Device settling”
“Device ranging”
“Device sweeping”
“Device measuring”
SE
SE
SE
SE
SE
SE
+126
+161
+171
+172
+173
+174
“Device calculating”
“Program running”
“Waiting in trigger Layer”
“Waiting in arm layer 1”
“Waiting in arm layer 2”
“Re-entering the idle layer”
SE
SE
SE
SE
SE
SE
+301
+302
+303
+304
+305
“Reading overflow”
“Low limit 1 event”
“High limit 1 event”
“Low limit 2 event”
“High limit 2 event”
SE
SE
SE
SE
SE
+306
+307
+308
+309
+310
“Reading Available”
“Voltmeter Complete”
“Buffer Available”
“Buffer half full”
“Buffer full”
SE
SE
SE
SE
SE
+311
+312
+313
+315
+320
+321
+322
“Buffer Overflow”
“Buffer Pretriggered”
“Reading out of Limit”
“V-Source compliance detected”
“Buffer & Format element mismatch”
“Buffer Sizing error; set to MAX”
“Buffer Sizing error; set to MIN”
SE
SE
SE
SE
EE
EE
EE
Table 2-5 (cont.)
Status and error messages
Number
Description
Event
Содержание 6517A
Страница 1: ...Model 6517A Electrometer User s Manual A G R E A T E R M E A S U R E O F C O N F I D E N C E...
Страница 310: ...A Specifications...
Страница 311: ...A Specifications...