A-4
Specifications
GENERAL
DISPLAY:
6
1
⁄
2
-digit vacuum fluorescent.
OVERRANGE INDICATION:
Display reads “OVRFLOW”.
RANGING:
Automatic or manual.
CONVERSION TIME:
Selectable 0.01 PLC to 10 PLC.
PROGRAMS:
Provide front panel access to IEEE address, choice of engineering
units or scientific notation, and digital calibration.
MAXIMUM INPUT:
250V peak, DC to 60Hz sine wave; 10s per minute maximum on
mA ranges.
MAXIMUM COMMON MODE VOLTAGE (DC to 60Hz sine wave):
Electrometer,
500V peak;
ISOLATION (Meter COMMON to chassis):
Typically 1010
Ω
in parallel with 500pF.
INPUT CONNECTOR:
Three lug triaxial on rear panel.
2V ANALOG OUTPUT:
2V for full range input. Inverting in Amps and Coulombs
mode. Output impedance 10k
Ω
.
PREAMP OUTPUT:
Provides a guard output for Volts measurements. Can be used
as an inverting output or with external feedback in Amps and Coulombs modes.
DIGITAL INTERFACE:
Handler Interface:
Start of test, end of test, 3 category bits.
Digital I/O:
1 Trigger input, 4 outputs with 500mA sink capability.
Connector:
9 Pin D subminiature, male pins.
EMC:
Conforms with European Union Directive 89/336/EEC EN55011,
EN50082-1, EN61000-3-2, EN61000-3-3, FCC part 15 class B.
SAFETY:
Conforms with European Union Directive 73/23/EEC EN61010-1.
GUARD:
Switchable voltage and ohm guard available.
TRIGGER LINE:
Available, see manual for usage.
READING STORAGE:
2500 readings.
READING RATE:
To internal buffer 1200 readings/second1
To IEEE-488 bus
500 readings/second1,3
To front panel
17 readings/second at 60Hz;2
15 readings/second at 50Hz2
Notes:
1 0.01 PLC, digital filters off, front panel off, auto zero off.
2 1.00 PLC, digital filters off.
3 Binary transfer mode.
DIGITAL FILTER:
Median and averaging (selectable from 2 to 100 readings).
DAMPING:
User selectable on Amps function.
ENVIRONMENT:
Operating:
0°–50°C; relative humidity 70% non-condensing, up to 35°C.
Storage:
–25° to +65°C.
WARM-UP:
1 hour to rated accuracy (see manual for recommended procedure).
POWER:
90–125V or 210–250V, 50–60Hz, 60VA.
PHYSICAL:
Case Dimensions:
90mm high
×
214mm wide
×
369mm deep
(3
1
⁄
2
in.
×
8
3
⁄
8
in.
×
14
9
⁄
16
in.).
Working Dimensions:
From front of case to rear including power cord and
IEEE-488 connector: 15.5 inches.
Net Weight:
<4.6 kg (<10.1 lbs).
Shipping Weight:
<9.5 kg (<21 lbs).
Section A pg 2-4 5/5/03 1:57 PM Page 3
Содержание 6514
Страница 203: ...14 CommonCommands...
Страница 207: ...15 SCPISignalOriented MeasurementCommands...
Страница 235: ...18 PerformanceVerification...
Страница 254: ...19 Calibration...
Страница 274: ...20 RoutineMaintenance...
Страница 278: ...A Specifications...
Страница 282: ...B StatusandErrorMessages...
Страница 288: ...C GeneralMeasurement Considerations...
Страница 294: ...D DDCEmulationCommands...
Страница 299: ...E ExamplePrograms...
Страница 306: ...F IEEE 488BusOverview...
Страница 320: ...G IEEE 488andSCPI ConformanceInformation...
Страница 324: ...H CalibrationOptions...