Model 2750 Multimeter/Switch System User’s Manual
SCPI Reference Tables
15-17
[SENSe[1]]
:FREQuency
Path to configure frequency.
:APERture <NRf>
[, <clist>]
Sets gate time for frequency
measurements in seconds (0.01 to 1.0).
1.0
:APERture? [<clist>]
Query frequency gate time.
:DIGits <n> [, <clist>]
Specify measurement resolution (4 to 7).
7
:DIGits? [<clist>]
Query resolution.
:REFerence <n> [, <clist>]
Specify reference (0 to 1.5e7).
0
:STATe <b> [, <clist>]
Enable or disable reference.
OFF
:STATe? [<clist>]
Query state of reference.
:ACQuire [, <clist>]
Use input signal as reference.
:REFerence? [<clist>]
Query reference value.
:THReshold
Path to select the threshold voltage range:
✓
:VOLTage
✓
:RANGe <n> [, <clist>]
Select threshold range (0 to 1010).
10
:RANGe? [<clist>]
Query threshold range.
:PERiod
Path to configure period:
:APERture <NRf>
[, <clist>]
Sets gate time for period measurements in
seconds (0.01 to 1.0).
1.0
:APERture? [<clist>]
Query period gate time.
:DIGits <n> [, <clist>]
Specify measurement resolution (4 to 7).
7
:DIGits? [<clist>]
Query resolution.
:REFerence <n> [, <clist>]
Specify reference (0 to 1).
0
:STATe <b> [, <clist>]
Enable or disable reference.
OFF
:STATe? [<clist>]
Query state of reference.
:ACQuire [, <clist>]
Use input signal as reference.
:REFerence? [<clist>]
Query reference value.
:THReshold
Path to select the threshold voltage range:
:VOLTage
:RANGe <n> [, <clist>]
Select threshold range (0 to 1010).
10
:RANGe? [<clist>]
Query threshold range.
Table 15-5 (continued)
SENSe command summary
Command
Description
Default
parameter
Ref
SCPI
2750-900-01.book Page 17 Wednesday, August 3, 2011 7:56 AM
Содержание 2750
Страница 3: ...2750 900 01 book Page 2 Wednesday August 3 2011 7 56 AM...
Страница 7: ...2750 900 01 book Page 4 Wednesday August 3 2011 7 56 AM...
Страница 17: ...2750 900 01 book Page 10 Wednesday August 3 2011 7 56 AM...
Страница 204: ...Model 2750 Multimeter Switch System User s Manual Buffer 6 15 2750 900 01 book Page 15 Wednesday August 3 2011 7 56 AM...
Страница 205: ...6 16 Buffer Model 2750 Multimeter Switch System User s Manual 2750 900 01 book Page 16 Wednesday August 3 2011 7 56 AM...
Страница 324: ...12 CommonCommands 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 332: ...13 SCPISignalOriented MeasurementCommands 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 348: ...15 SCPIReferenceTables 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 374: ...B Model7700ConnectionGuide 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 386: ...C StatusandErrorMessages 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 394: ...D SignalProcessing SequenceandDataFlow 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 408: ...E MeasurementConsiderations 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Страница 428: ...G IEEE 488BusOverview 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...