8.4
Pt500 short direct sensor set
The Pt500 short direct sensor is constructed according to the European standard for thermal heat meters
EN 1434-2. The sensor is constructed for fitting directly in the measuring medium, i.e. without sensor pocket. In
this way an extremely fast response time on temperature changes from e.g. domestic water exchangers is obtained.
The sensor is based on a 2 wire silicone cable. The sensor tube is made of stainless steel and has a diameter of ø4
mm at the tip where the sensor element is placed. Fitting can also be made directly in many flow sensor types,
which reduces the installation costs.
Figure 8
Figure 9
Figure 10
The sensor is fitted in special T-sections, that is
available for ½”, ¾” and 1” pipe installations.
In addition, the short direct sensor is fitted by
means of a R½ or R¾ for M10 nipple in a
standard 90
tee.
To obtain the best serviceability during meter replacements, the short
direct sensor can be placed in a ball valve with a sensor connecting piece.
Ball valves with sensor connecting piece are available in G½, G¾, G1,
G1¼ and G1½
No.
6556-474 6556-475 6556-476 6556-526 6556-527
G½
G¾
G1
G1¼
G1½
Recommended
temperature sensor
DS 27.5 mm DS 27.5 mm DS 27.5 mm
DS 38 mm
DS 38 mm
Max. 130 °C and PN16