MULTICAL®
602
34
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
602-C
Application No. 6
Open system with separate flow sensor for tap water
Heat energy: E1 = V1(T1-T2)k
T2:Outlet
Tap water energy: E6 = V2 (T3-T4)k
T3:Inlet
T3 is measured or programmed
T4 is programmed
Mass: M1 = V1 (Kmass t2)
Mass: M2 = V2 (Kmass t3)*
602-C
Application No. 7
Open system with 2 flow sensors
Inlet energy: E4 = V1 (T1-T3)k
T1:Inlet
Outlet energy: E5 = V2 (T2-T3)k
T2:Inlet
(
Δ
E = E4-E5 can be calculated by the top module 67-
02, but only if the 2 flow sensors are identical. The
DDD-code must be selected to have energy (e.g. E1)
as default primary reading, and when the top module
67-02 is installed the primary reading will be
Δ
E
instead)
Heat energy: E2 = V2 (T1-T2)k
T2:Outlet
T3 is measured or programmed.
Mass: M1 = V1 (Kmass t1)
Mass: M2 = V2 (Kmass t2)
602-C
Application No. 8
Hot-water boiler with circulation
Total consumption: E1 = V1 (T1-T2)k
T2:Outlet
Circulated consumption: E7 = V2 (T1-T3)k
T3: Outlet
* M2 = V2 (Kmass t3)* only on selected country codes (930…939)!