MULTICAL®
602
32
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
6.2
Application types
MULTICAL
602 operates with 9 different energy formulas, E1…E9, that are all calculated in parallel with each
integration no matter how the meter is configured.
Formula
Example of an application
Included in Application No.
Register type
E1=V1(T1-T2)k
T1: Inlet / T2: Outlet
T1
>
T2
Heat energy (V1 in inlet or outlet pipe)
1+2+3+4+5+6+8+10
Legal
Display/Data/Log
E2=V2(T1-T2)k
T2: Outlet
T1
>
T2
Heat energy (V2 in outlet inlet)
2+7
Display/Data/Log
E3=V1(T2-T1)k
T2: Inlet / T1: Outlet
T2
>
T1
Cooling energy (V1 in inlet or outlet pipe)
1+11
Legal
Display/Data/Log
E4=V1(T1-T3)k
T1: Inlet
T1
>
T3
Inlet energy
7+9+11
Display/Data/Log
E5=V2(T2-T3)k
T2: Inlet
T2
>
T3
Outlet energy or tap from outlet pipe
5+7+9
Display/Data/Log
E6=V2(T3-T4)k
T3: Inlet
T3
>
T4
Tap water energy, separate
3+6
Display/Data/Log
E7=V2(T1-T3)k
T3: Outlet
T1
>
T3
Outlet energy or tap from inlet pipe
4+8
Display/Data/Log
E8=m
3
x T1
-
Average temperature in inlet pipe
See paragraph 6.2.2
Display/Data/Log
E9=m
3
x T2
-
Average temperature in outlet pipe
Display/Data/Log
6.2.1
E1…E7
The energy types E1…E7 are described with application examples below.
602-A/B/C/D
Application No. 1
Closed thermal system with 1 flow sensor
Heat energy: E1 = V1(T1-T2)k
T1:Inlet or T2:Outlet
Cooling energy: E3 = V1 (T2-T1)k
T2:Inlet or T1: Outlet
Flow sensor V1 is placed in inlet or outlet pipe as
chosen under PROG options.
Mass: M1 = V1 (Kmass t1) or
Mass: M1 = V1 (Kmass t2) depending on the
Inlet/Outlet programming
602-C
Application No. 2
Closed thermal system with 2 identical flow sensors
Billing energy: E1 = V1(T1-T2)k
T1:Inlet
Control energy: E2 = V2 (T1-T2)k
T2:Outlet
T3 can be used for control measurement of either the
inlet or outlet temperature, but T3 is not included in
calculations.
Mass: M1 = V1 (Kmass t1)
Mass: M2 = V2 (Kmass t2)