Example: Power tariff (EE=11); TL2=20 kW; TL3=30 kW; the meter is a heat meter.
The heat energy E1 is always counted in the main register. When the power exceeds the limit set for TL2, i.e. 20 kW,
but is below the limit set for TL3, i.e. 30 kW, the heat energy E1 is counted in TA2, but only as long as TL2 exceeds
20 kW and is lower than 30 kW. It functions as a contact T2, which closes the moment TL2 surpasses 20 kW. As
soon as the power either surpasses 30 kW or falls below 20 kW, the contact breaks again and counting stops in the
TA-register. If the power surpasses 30 kW the contact T3 closes and now all the energy E1, which is consumed as
long as the power remains above 30 kW is counted in T3. This energy E1 is counted in both the main register and
in TA3.
EE= TARIFF
TYPE
FUNCTION
Cou
n
tr
y code
2xx
Cou
n
tr
y code
4xx
Cou
n
tr
y code
5xx
Cou
n
tr
y code
6xx
Cou
n
tr
y code
7xx
Cou
n
tr
y code
8xx
Cou
n
tr
y code
9xx
00
No tariff active
No
function
11
Power tariff
Energy is accumulated in TA2 and TA3 based on the power limits in
TL2 and TL3.
12
Flow tariff
Energy is accumulated in TA2 and TA3 based on the flow limits in
TL2 and TL3.
13
Cooling tariff
Energy is accumulated in TA2 and TA3 based on the
t limits in TL2
and TL3.
14
Inlet temperature tariff
Energy is accumulated in TA2 and TA3 based on the tF-limits in
TL2 and TL3.
15
Outlet temperature tariff
Energy is accumulated in TA2 and TA3 based on the tR-limits in TL2
and TL3.
19
Time-controlled tariff
TL2=Starting time for TA2
TL3=Starting time for TA3
20
Heat/cooling volume tariff
(TL2 and TL3 are not used)
Volume (V1) is split up into TA2 for heat (T1
T2) and TA3 for
cooling (T1
T2) (Recommended on Heating/Cooling applications)
21
PQ tariff
Energy at P
TL2 is stored in TA2 and energy at Q
TL3 is stored in
TA3
Please note that only tariff No. 20 can be used in a combined heat / cooling meter. All other tariffs may only be
used for either a heat meter or a cooling meter. The meter can not distinguish heat energy (E1) from cooling
energy (E3) and vice versa.
See paragraph 6.12 for further details on the tariff registers.