MULTICAL®
602
18
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
3.3.6
CCC codes with high resolution for ULTRAFLOW
(for cooling meters etc.)
Number of decimals on the display
CCC
no.
Pre-
counter
Flow
factor
kWh
MWh
Gcal
GJ
m³
ton
l/h
m³/h
kW
MW
Pulses/l
qp
m³/h
Type no.
Flow sensor
184
300
78642
1
-
3
3
0
-
1
-
300
0.6
1-2-7-8-K-M
107
100
235926
1
-
3
3
0
-
1
-
100
1.5
1-2-7-8-K-M
136
500
471852
0
3
2
2
0
-
1
-
50.0
3.5
1-2-7-8-K-M
138
250
943704
0
3
2
2
0
-
1
-
25.0
6.0
10
1-2-7-8-K-M
183 150
1572840
0 3 2 2 0 - 1 - 15.0
10
1-2-7-8-K-M
185 100
2359260
0 3 2 2 0 - 1 - 10.0
15
1-2-7-8-K-M
186
500
471852
-
2
1
1
-
2
0
-
5.0
40
1-2-7-8-K-M
187
250
943704
-
2
1
1
-
2
-
3
2.5
60
1-2-7-8-K-M
188 150
1572840
- 2 1 1 - 2 - 3 1.5 100
1-2-7-8-K-M
189 100
2359260
- 2 1 1 - 2 - 3 1.0 150
1-2-7-8-K-M
191
400
589815
-
1
0
0
-
1
-
2
0.4
400
1-2-7-8-K-M
192
250
943704
-
1
0
0
-
1
-
2
0.25
600
1000
1-2-7-8-K-M
193
150
1572840
-
1
0
0
-
1
-
2
0.15
1000
1-2-7-8-K-M
Current flow reading (l/h or m³/h) is calculated on the basis of volume pulses/10 s (see paragraph 6.5)
3.3.7
CCC codes for other electronic meters with a passive output
Number of decimals on the display
CCC
no.
Pre-
counter
Flow
factor
MWh
Gcal
GJ
m³
ton
m³/h
kW
MW
l/pulse
Pulses/l
Qmax
m³/h
Type
Flow
sensor
147 1000 2359260 1 0 0
2
-
3
1
-
18...75
SC-18
K-M
148 400
5898150
1 0 0 2 - 3
2.5
- 120…300
SC-120 K-M
149 100
2359260
1 0 0 1 - 2
10
- 450…1200
SC-450 K-M
150 20
11796300
1
0
0 1 - 2
50
- 1800…3000
SC-1800 K-M
175 7500 314568 1 0 0
2
-
3
-
7.5 15…30
DF-15 K-M
176 4500 524280 1 0 0
2
-
3
-
4.5 25…50
DF-25 K-M
177 2500 943704 1 0 0
2
-
3
-
2.5 40…80
DF-40 K-M
Number of decimals on the display
CCC
no.
Pre-
counter
Flow
factor
MWh
Gcal
GJ
m³
ton
m³/h
MW
l/pulse
Pulse/l
Qp range
m³/h
Qs
(m³/h)
Type
Flow
sensor
201 100 235926
2 1 1 1 2
1
1 10…100
75
FUS380
DN50-65
K-M
202 40 589815
2
1
1 1 2 2.5
0.4 40…200
240
FUS380
DN80-100
K-M
203 400 589815
1 0 0 1 2 2.5
0.4 100…400
500
FUS380
DN125
K-M
204 100 235926
1 0 0 0 1
10
0.1 150…1200
1600
FUS380
DN150-250
K-M
205 20
1179630
1
0
0 0 1 50
0.02 500…3000
3600
FUS380
DN300-400
K-M
Current flow reading (l/h or m³/h) is calculated on the basis of volume pulses/10 pcs. (see paragraph 6.5)
3.3.8
CCC codes for other electronic meters with an active output
Flow sensor with active 24 V pulse output, see paragraph 7.2