MULTICAL®
602
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
25
3.6
>FF< Input A (VA) - pulse divider, >GG< Input B (VB) - pulse divider
MULTICAL
®
602 has 2 extra pulse inputs, VA and VB, that are placed on the base modules (see paragraph 7.3 for
further information). The inputs are configured via the FF and the GG codes as shown in below diagram.
By default the inputs are configured to FF = 24 and GG = 24, unless otherwise informed by the customer.
Input A
Terminal 65-66
Input B
Terminal 67-68
FF
Max. input
f
1Hz
GG
Max. input
f
1 Hz
Pre-counter Wh/pulses l/pulse
Measuring unit and decimal
point
Pulse input with bounce damping (for meters with Reed-switch):
01
100 m³/h
01
100 m³/h
1 -
100
vol A/vol b (m
3
)
000000.0
02
50 m³/h
02
50 m³/h
2 - 50
vol A/vol b (m
3
)
000000.0
03
25 m³/h
03
25 m³/h
4 - 25
vol A/vol b (m
3
)
000000.0
04
10 m³/h
04
10 m³/h
10 - 10
vol A/vol b (m
3
)
000000.0
05
5 m³/h
05
5 m³/h
20 - 5.0
vol A/vol b (m
3
)
000000.0
06
2.5 m³/h
06
2.5 m³/h
40 - 2.5
vol A/vol b (m
3
)
000000.0
07
1 m³/h
07
1 m³/h
100 - 1.0
vol A/vol b (m
3
)
000000.0
24
10 m³/h
24
10 m³/h
1
-
10
vol A/vol b (m
3
)
00000.00
25
5 m³/h
25
5 m³/h
2 - 5.0
vol A/vol b (m
3
)
00000.00
26
2.5 m³/h
26
2.5 m³/h
4 - 2.5
vol A/vol b (m
3
)
00000.00
27
1 m³/h
27
1 m³/h
10 - 1.0
vol A/vol b (m
3
)
00000.00
40
1000 m³/h
40
1000 m³/h
1 -
1000
vol A/vol b (m
3
)
0000000
Pulse input without bounce damping (for meters with electronic pulse output):
71
100 m³/h
71
100 m³/h
1
-
100
vol A/vol b (m
3
)
000000.0
72
50 m³/h
72
50 m³/h
2
-
50
vol A/vol b (m
3
)
000000.0
73
25 m³/h
73
25 m³/h
4
-
25
vol A/vol b (m
3
)
000000.0
74
10 m³/h
74
10 m³/h
10
-
10
vol A/vol b (m
3
)
000000.0
75
5 m³/h
75
5 m³/h
20
-
5.0
vol A/vol b (m
3
)
000000.0
76
2.5 m³/h
76
2.5 m³/h
40
-
2.5
vol A/vol b (m
3
)
000000.0
77
1 m³/h
77
1 m³/h
100
-
1.0
vol A/vol b (m
3
)
000000.0
84
10 m³/h
84
10 m³/h
1 - 10
vol A/vol b (m
3
)
00000.00
85
5 m³/h
85
5 m³/h
2 - 5.0
vol A/vol b (m
3
)
00000.00
86
2.5 m³/h
86
2.5 m³/h
4 - 2.5
vol A/vol b (m
3
)
00000.00
87
1 m³/h
87
1 m³/h
10 - 1.0
vol A/vol b (m
3
)
00000.00
90
1000 m³/h
90
1000 m³/h
1 -
1000
vol A/vol b (m
3
)
0000000
FF
Max. Input
f
3 Hz
GG
Max. Input
f
3 Hz
Pre-counter Wh/pulses l/pulses
Measuring unit and decimal
point
50
2500 kW
50
2500 kW
1
1000
-
EL A/EL b (kWh)
0000000
51
150 kW
51
150 kW
60
16.67
-
EL A/EL b (kWh)
0000000
52
120 kW
52
120 kW
75
13.33
-
EL A/EL b (kWh)
0000000
53
75 kW
53
75 kW
120
8.333
-
EL A/EL b (kWh)
0000000
54
30 kW
54
30 kW
240
4.167
-
EL A/EL b (kWh)
0000000
55
25 kW
55
25 kW
340
2.941
-
EL A/EL b (kWh)
0000000
56
20 kW
56
20 kW
480
2.083
-
EL A/EL b (kWh)
0000000
57
15 kW
57
15 kW
600
1.667
-
EL A/EL b (kWh)
0000000
58
7,5 kW
58
7,5 kW
1000
1.000
-
EL A/EL b (kWh)
0000000
59
750 kW
59
750 kW
10
100
-
EL A/EL b (kWh)
0000000
60
1250 kW
60
1250 kW
2
500
-
EL A/EL b (kWh)
0000000
61
75 kW
61
75 kW
100
10.00
-
EL A/EL b (kWh)
0000000
62
15 kW
62
15 kW
500
2.000
-
EL A/EL b (kWh)
0000000
70
25000 kW
70
25000 kW
1
10000
-
EL A/EL b (MWh)
00000.00
FF and GG are only used for configuration of inputs.
l/pulse can also be set via the front bottons. Please see 6.17 for further information.