Preset the pulse value for V1 and V2
It is possible to preset the pulse value for V1 and V2 in MULTICAL
®
602 by changing the CCC-codes. In order to do
so the meter must be connected via an optical eye to a PC with the METERTOOL software running. Break the
verification seal and short circuit the TOTAL PROG button on the inside of the calculator top with a short circuit
pen.
Note!
This should only be done by an accredited laboratory, since breaking of the verification seal revokes the
legal verification as well as the factory warranty.
After shorting the total programming circuit, the meter is set in programming mode for 4 minutes. Set the pulse
value by selecting a suitable CCC-code. As long as METERTOOL is communicating with the meter, the time for
programming mode is extended, and after 4 minutes of inactivity the meter will return to normal mode. When the
desired pulse values for V1 and V2 are set, METERTOOL can be used to terminate the programming mode by a
reset, and the meter returns to normal mode ready for use.