MULTICAL®
602
44
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
6.9
Display functions
MULTICAL
602 is equipped with a clear LC display including 8 digits, units of measurement and information panel.
In connection with energy and volume readings 7 digits and the corresponding units of measurement are used,
whereas 8 digits are used when e.g. a meter number is shown.
As a starting point the display shows the accumulated energy. When the push buttons are activated the display
reacts immediately by showing other readings. The display automatically returns to energy reading 4 minutes after
last activation of the push buttons.
6.9.1
Primary and secondary readings
The upper button is used to switch between the primary readings of which the consumers typically use the first
primary readings in connection with self-reading for billing purposes.
The lower push button is used to show secondary information on the primary reading that has been selected.
Example: When the primary reading selected is "Heat energy" the secondary readings will be yearly data and
monthly data for heat energy.
Heat energy E1 in MWh
Yearly data, date for LOG 1 (last yearly reading)
Yearly data, value for LOG 1 (last yearly reading)
Monthly data, date for LOG 1 (last monthly reading)
Содержание MULTICAL 602
Страница 2: ...MULTICAL 602 2 Kamstrup A S Technical Description 5512 931_N1_GB_11 2016 ...
Страница 70: ...MULTICAL 602 70 Kamstrup A S Technical Description 5512 931_N1_GB_11 2016 7 2 1 Connection examples ...
Страница 130: ...MULTICAL 602 130 Kamstrup A S Technical Description 5512 931_N1_GB_11 2016 ...